DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
4005126-03
© 2016, Miles Industries Ltd. All rights reserved.
H
ORIZON
DV Gas Fireplace Heater
534JN (NG) & 534JP (LPG)
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the EN-
GINE ONLY. A front trim kit is REQUIRED to install
the engine as it affects the framing cavity and posi-
tion of the engine. A barrier screen is provided with
the front or trim kit. Refer to the manual supplied
with the front for framing and fi nishing.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor HORIZON 534JN

  • Page 1 ORIZON DV Gas Fireplace Heater 534JN (NG) & 534JP (LPG) Installation & Owner’s Manual DANGER I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2016...
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully Due to the high temperature, the appliance should be before starting the installation. FAILURE TO FOLLOW LOCATED out of traffi c areas and away from furniture these installation instructions may result in possible fi re and draperies.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, A physical barrier is strongly • recommended if there are young Parts of your Valor Fireplace become • children, or at-risk individuals in the extremely hot while in operation. house. Install an approved after- The glass viewing window •...
  • Page 5: Owner's Information

    For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages is fully tested during the production process for your 3 and 4 of this manual BEFORE operating safety and comfort.
  • Page 6: Cleaning Your Fireplace

    OWNER’S Owner’s Information INFORMATION Cleaning Your Fireplace To remove the window for cleaning: 1. Unhook the front or trim with barrier screen WARNING attached. 2. Turn the top two spring- DO NOT TOUCH THE GLASS WHILE IT IS HOT! loaded window bolts Let the fi...
  • Page 7: Checking Pilot And Burner Flames

    Pilot Flame can be seen Damage caused by incorrect window installa- between left front and top logs tion is not covered by the Valor warranty. 6. If the Hot Glass Warning plate has been removed from the front lower corner of the window, reinstall it by sliding it between the glass and the frame as indicated.
  • Page 8: Replacing Batteries

    OWNER’S Owner’s Information INFORMATION Replacing Batteries To access the card, remove any fret or access panel and grab the card and slide it out to read it. There is WARNING important information on both sides of the card. DO NOT ATTEMPT TO CHANGE THE BATTER- Servicing Your Fireplace IES WHILE THE FIREPLACE IS STILL HOT! Let If any attention is required for your appliance, contact...
  • Page 9: How To Ensure Your Fireplace Cannot Be Turned On Inadvertently

    OWNER’S Owner’s Information INFORMATION If the fl ames are on, they go down and you hear the valve motor wind down. You hear a clunk and a beep indicating that the valve has received the signal from the remote control. Manual ON/OFF Switch: Press the O button.
  • Page 10: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 11 OWNER’S Remote Control Operation INFORMATION • Press and hold (small fl ame) MODES OF OPERATION button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” TEMPERA- SETTING THE “DAYTIME” TEMPERATURE TURE Default Settings: (sun), 23ºC / 74ºF Default Settings: (moon), “ ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 13 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 14 OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ ☼ 6:00 a.m.— ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 15: Options

    Refl ective Glass Liners 1265WSK Wall Switch Kit 620FBL Fluted Black Liners RBWSK Remote Battery & Wall Switch Kit 621VRL Valor Red Brick Liners 755CFK Circulating Fan Kit 622LSL Ledgestone Liners Hearth Hearth gates such as Cardinal’s VersaGates are available at retail stores...
  • Page 16: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 17: Commonwealth Of Massachusetts

    QUALIFIED Commonwealth of Massachusetts INSTALLER State of Massachusetts Carbon Monoxide 3. SIGNAGE. A metal or plastic identifi cation plate shall be permanently mounted to the exterior of the Detector/Vent Terminal Signage building at a minimum height of eight (8) feet above Requirements grade directly in line with the exhaust vent terminal for For all side wall horizontally vented gas fueled...
  • Page 18 QUALIFIED Commonwealth of Massachusetts INSTALLER (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi...
  • Page 19: Specifi Cations

    QUALIFIED Specifi cations INSTALLER Approvals & codes Supply Gas These appliances are certifi ed by ANSI Z21.88-2014/CSA Heater engine units 534JN is used with natural gas 2.33-2014 American National Standard / CSA Standard installations. for Vented Gas Fireplace Heaters for use in Canada and Heater engine units 534JP is used with propane gas USA.
  • Page 20: Overview

    QUALIFIED Overview INSTALLER Mantel—See Dimensions Remote Handset Wall section for mantel clearances Holder Framing—See Framing section Fire On/Off Wall Switch (optional) Field convertible Front with screen (required) from top to rear (Contemporary Front outlet 601SFB shown—sold separately) Wall Finish May be combustible (see note above).
  • Page 21: Dimensions

    QUALIFIED Dimensions INSTALLER 7” (180 mm) Stand-offs From finished wall front to top vent 1-1/2” (38 mm) Stand-offs 3” (75 mm) min. To side wall from inner frame 4-1/2” in front of (114 mm) the appliance 36” (914 mm) min. See table 32-3/16”...
  • Page 22: Framing

    QUALIFIED Framing INSTALLER • A non-combustible hearth is not necessary in front of this appliance. • Note that the unit is installed at the framing stage and fi xed to framing using support angles. See page 30. Wall fi nish is then installed over the support angles up to the black frame on the unit. NOTE: If using a 613CCB front, refer to the kit’s instruction manual for framing dimensions.
  • Page 23: Location

    QUALIFIED Location INSTALLER Venting Vent Material Vent Penetration through Walls & Ceilings This unit is approved for installation using 4 x 6-5/8 Combustible: When penetrating through combustible inches approved co-axial direct vent pipes and acces- walls and ceilings, frame a minimum of 10 inch x 10 sories listed on pages 43–44 of this guide.
  • Page 24: Co-Axial Venting

    QUALIFIED Co-Axial Venting INSTALLER Typical Co-Axial Venting Components VERTICAL TERMINATION STORM COLLAR FLASHING ATTIC INSULATION SHIELD HORIZONTAL 2-PIECE TERMINATION WALL ATTIC THIMBLE FIRESTOP CEILING FIRESTOP PIPE 90˚ ELBOW PIPE LENGTH LENGTH PIPE LENGTH PIPE LENGTH 817VAK 817VAK...
  • Page 25 QUALIFIED Co-Axial Venting INSTALLER Rear Vent with No Vertical Rise The horizontal vent run cannot be extended by the use of any vent accessory pipes. 26” (66 cm) max. vent length (14” (36 cm) max. Vent pipe max. enclosed within 15”...
  • Page 26 QUALIFIED Co-Axial Venting INSTALLER Horizontal Vent Termination Location or a safety hazard. Local codes or regulations may require greater clearances. • The vent terminal must be located on an outside • The vent terminal must not be recessed into a wall wall or through the roof.
  • Page 27 QUALIFIED Co-Axial Venting INSTALLER Co-Axial Venting Confi gurations with Vertical Rise 4 x 90º ELBOWS MAXIMUM (or equivalent) 3” min. above top of horizontal pipe 1” min. all around vertical pipe 1” min. around bottom & sides of horizontal pipe Min.
  • Page 28 QUALIFIED Co-Axial Venting INSTALLER How to Read the Venting Chart 5. Each 90 degrees elbow installed on the horizontal plane is equivalent to a 3 feet horizontal pipe; The chart below applies to co-axial roof or wall therefore, 3 feet must be subtracted from allowable termination in installations with vertical rise.
  • Page 29 QUALIFIED Co-Axial Venting INSTALLER Co-Axial Vertical Installations Overhang should • Check the roof pitch to determine which roof not extend beyond vent if within 48” of fl ashing will be needed. See venting accessories list Horizontal termination cap on pages 45–46 for allowable components. overhang •...
  • Page 30: Co-Linear Venting

    Secure the appliance to the fl oor or wall if necessary. Rear or Top Outlet Conversion to Co-Linear 2 x 3” liners engine Liners using Valor 556CLA Co-Linear Adapter. Co-linear (Generic co-axial to co-linear adapter boxes may also be used as an adapter alternate to the 556CLA).
  • Page 31: Installation

    QUALIFIED Installation INSTALLER Remove Window 1. Turn the top two spring-loaded window bolts through 90 degrees to release the window from the fi rebox. 2. Remove the bottom two spring-loaded window bolts. 3. Carefully lift the window away. Keep the window and bolts in a safe place. Convert to Rear Vent Outlet (if required) If installing with top vent outlet, ignore this stage.
  • Page 32: Install Top Heat Shield & Stand-Offs

    QUALIFIED Installation INSTALLER Install Top Heat Shield & Stand-offs Shield to rest 1. If installing appliance with top vent outlet, on 2 supports remove the plate covering the vent hole in the top heat shield by unscrewing four screws. If installing with rear vent outlet, the plate must remain to cover the hole.
  • Page 33: Install Air Restrictors

    QUALIFIED Installation INSTALLER Install Air Restrictors No restrictors are required for appliances which only have a horizontal vent run. If installing an appliance which has a rear vent outlet connection and no vertical vent pipe rise, ignore this stage. Two restrictor sets, like the one shown at right, are supplied with each 534 engine unit.
  • Page 34: Re-Install Rear Log Support

    QUALIFIED Installation INSTALLER Re-install Rear Log Support Refi t the rear log support in place (5 screws). Reinstall rear support Install Appliance Into Framing 1. Place the heater in position in the framing. 2. Secure the side support angles to the side studding through two holes each side with the woodscrews supplied.
  • Page 35: Connect Gas Supply

    QUALIFIED Installation INSTALLER Connect Gas Supply » The appliance must be isolated from the gas supply piping system by closing its individual • The gas supply pipe should enter the appliance manual shut-off valve during any pressure case through the opening at the left side. The supply testing of the gas supply piping system at pipe should be connected to the appliance gas inlet test pressures equal to or less than 1/2 psig...
  • Page 36: Install Liner Panels

    QUALIFIED Installation INSTALLER Install Liner Panels 4. Insert the top panel over the left side panel while holding the top panel forward up the slope. Rotate All liner panels can be installed as indicated below the right side of the top panel upwards and place it except the 618RGL—Refl...
  • Page 37: Install 534Lsk Ceramic Logs

    QUALIFIED Installation INSTALLER Install 534LSK Ceramic Logs Unpack the ceramic logs very carefully to avoid damaging their fragile material. Install the logs as shown below. Please note that the position of the logs is critical to insure the good performance of the appliance. 1.
  • Page 38 QUALIFIED Installation INSTALLER 6. Place the lower end of the center right log onto the pin on the front right log. Rest the narrow end in the notch into the rear log. Notch in rear log Pin in front right log 7.
  • Page 39: Install 534Rsk Ceramic Rocks

    QUALIFIED Installation INSTALLER Install 534RSK Ceramic Rocks Unpack the ceramic rocks kit very carefully to avoid damaging the fragile material. Install the components as shown below. Please note that the position of the rocks and twigs (if used) is critical to ensure proper performance of the appliance.
  • Page 40 QUALIFIED Installation INSTALLER 4. The underside of each ceramic rock is identi- fi ed by a number and a specifi c protruding positioning triangle. Rock Install the six rocks from left to right starting identifi cation with rock no. 1. Triangular hole in Note: The ceramic base may need to be slightly...
  • Page 41: Refi T And Check Window

    WARNING Failure to install the window correctly can leak carbon monoxide, affect the performance of the fi replace, damage components, cause overheating resulting in dangerous conditions. Damage caused by incorrect window installa- tion is not covered by the Valor warranty.
  • Page 42: Synchronize Remote Control To Handset

    QUALIFIED Installation INSTALLER Synchronize Remote Control to Handset The receiver and the handset of the remote control system must be initially synchronized before the fi rst use. 1. Insert alkaline batteries in the remote control receiver and handset. The receiver is located left of the control valve under the burner module.
  • Page 43: Install Front, Trim And Barrier Screen

    QUALIFIED Installation INSTALLER Install Front, Trim and Barrier Screen Install the front or trim chosen by the customer for their fi replace. Install as well the barrier screen which is provided with the front or trim. Show the customer how to access the controls when the front or trim are installed and how to remove them.
  • Page 44: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Optional Wall Switch Kit 1265WSK Connector Yellow GV60 Wiring Diagram...
  • Page 45: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 530 , 534, 650 and MF28 Venting Parts Code / availability by Manufacturer Venting Parts Description Standard Co-axial 46DVA-HC 4DT-HC TM-4HT — — 4DHC round 658DVK2 940160 Deluxe Co-axial —...
  • Page 46 658TG Notes: 1. All listed above co-axial pipes and fi ttings require Valor 817VAK Adapter Kit to fi t Valor’s smooth collars (Valor adapter 4DSC-V by American Metal Products may also be used). 2. Follow instructions supplied with each manufacturer’s components.
  • Page 47: Warranty

    The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase. Alternatively, the warranty registration form may be fi lled out online at www.valorfi replaces.com. b) Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation instructions.
  • Page 48: Replacement Parts

    16a Air shutter slider LPG 320B293 Refl ective Glass 618RGL 16b Air shutter slider NG 4002345 Ceramic fl uted black 620FBL Burner NG 740K189 Valor red brick 621VRL Burner LPG 740K190 Ledgestone 622LSL Injector elbow 82-650 NG 9730012 Rear panel Injector elbow 92-260 LPG 9730007 Refl...
  • Page 49 OWNER’S Replacement Parts INFORMATION Key Description Part no. Ledgestone 4002114 Log set complete 534LSK Rear log 4003795 Left top log 4003796 Right top log 4003797 Right center log 4003798 Left front log 4003800 Right front log 4003801 Loose coals pieces 4001843 Rock Set Complete 534RSK...
  • Page 50 OWNER’S Replacement Parts INFORMATION 45a, 45b...
  • Page 51: Miles Industries Ltd

    Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 52: Miles Industries Ltd

    Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

Horizon 534jp

Table of Contents