Vent Termination; Co-Axial + Co-Linear; Vent Terminal Location - Valor RetroFire RF24JDN Installation Manual

Direct vent gas
Table of Contents

Advertisement

Co-Axial with RA24CA
Co-Axial—5" x 3" flex
18"

Co-Axial + Co-Linear

Vent Terminal Location

The venting system for this appliance is considered to
be a Special Venting System. The rule in the Installation
Code CAN/CGA-B149 requiring a minimum vent height
of 2 feet above any portion of a building within 10 feet
does not, therefore, apply.
Clearances for Vent Terminals (Co-Linear and
Co-Axial)
Roof Pitch
Flat to 7/12
over 7/12 to 8/12
over 8/12 to 9/12
over 9/12 to 10/12
over 10/12 to 11/12
over 11/12 to 12/12
over 12/12 to 14/12
18
Approved 4" x 6-5/8"
co-axial terminal—
see list of approved
terminal in this manual
Terminal Adapter with
Flashiing supplied
with 590FVK2
18"
590FVK2
Minimum 'H'
(feet)
1'
1.5'
2'
2.5'
3.25'
4'
5'

Vent Termination

Vent Terminal Location
Horizontal
overhang
Termination
cap
Vertical
Min.
wall
18"
Storm
collar
Roof
flashing
Overhang should not
extend beyond vent if
within 48" of
termination cap
Min. 24"
(unvented soffit)
Min. 36"
(vented soffit)
'H'