9.0 APPLIANCE PREPARATION( Heater/Engine )

9.1 Detach the window

1.
Release the top of the window by pulling forward and rotating
outwards the two bars at the top corners. See figure 41.
2.
Unscrew the two spring loaded bolts securing the bottom of the
window. See figure 41.
3.
Carefully lift the window. Keep the window and bolts in a safe place.
4.
Remove ceramic Bricks/Logs/Coals from Firebox.

9.2 Check ignition spark

The pilot burner and electrode unit is at the left end of the burner.
Push in the lighting knob and turn counter-clockwise through the "IGN"
position to "PILOT". A spark should flash across from the pilot electrode
to the pilot burner shield. See figure 42.
Figure 42

9.3 Burner Module Removal

It may be desirable to remove the burner module to gain
access for gas fitting, to install a fan kit, or to fasten the unit
to the floor of plinth supplied with the zero clearance fronts.
See fig 43.
Figure 41