DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer,
service agency or the gas supplier.
4004962-11
©2018, Miles Industries Ltd. All rights reserved.
Portrait
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Please read this manual
BEFORE
operating this appliance.
INSTALLER
Leave this manual
with the appliance.
CONSUMER
Retain this manual
for future reference.
his manual contains instructions to install the EN-
GINE ONLY. A front trim kit is REQUIRED to install
the engine as it aff ects the framing cavity and posi-
tion of the engine. A barrier screen is provided with
the front or trim kit. Refer to the manual supplied
with the front for framing and fi nishing.
This appliance may be installed in an after-
market permanently located, manufactured
(mobile) home where not prohibited by local
codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in
a bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
installing and

Advertisement

Table of Contents
loading

Summary of Contents for Valor Portrait 530IN

  • Page 1 INSTALLATION & OWNER’S MANUAL Portrait Direct Vent Gas Fireplace 530IN (natural gas) & 530IP (propane gas) Please read this manual DANGER BEFORE installing and operating this appliance. HOT GLASS WILL CAUSE BURNS. INSTALLER DO NOT TOUCH GLASS Leave this manual UNTIL COOLED.
  • Page 2: Table Of Contents

    Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2018. All rights reserved.
  • Page 3: Safety And Your Fireplace

    Safety and Your Fireplace SAFETY AND YOUR FIREPLACE Read and understand all instructions carefully before Do not use this heater as a temporary source of starting the installation. Failure to follow these instal- heat during construction. lation instructions may result in possible fi re hazard and Due to the high temperature, the appliance should be will void the warranty.
  • Page 4 Safety and Your Fireplace Read and carefully follow all safety warnings and operating instructions contained in your owner’s manual Replacement manuals are available by contacting the Valor Service Department at 1-800-468-2567 or visit www.valorfi replaces.com. FOLLOW THESE IMPORTANT CHILD SAFETY...
  • Page 5 SAFETY AND YOUR FIREPLACE This manual and particularly the preceeding and following pages contain very important information regarding the safe operation of your fi replace as well as maintenance instructions. Read carefully before operating your fi replace and pay special attention to the safety warnings. A heating gas appliance does require safe handling.
  • Page 6: Introduction

    Each Valor fi replace curing compounds used in the manufacture of the is fully tested during the production process for your appliance.
  • Page 7: Operating Your Fireplace

    OWNER’S Operating Your Fireplace INFORMATION Fireplace Control Devices In the unlikely event that you cannot turn off your fi replace with the remote control handset, use the There are three ways to control your fi replace. wall switch (if installed); if the wall switch malfunctions 1.
  • Page 8: Using The Remote Control

    OWNER’S Using the Remote Control INFORMATION Current temperature Handset (F or C) sensor Period Battery status start or end (Temp, Timer) Current time (12 or 24 hour clock) Current programmed Modes (Manual, period (Timer) Temperature, Timer) Synchronize Remote Control BEFORE YOU BEGIN, please note that on this system, the settings of time, temperature and automatic ON/OFF can only be programmed when the function display is fl...
  • Page 9 OWNER’S Using the Remote Control INFORMATION M A N T E M P TEMP TIMER M A N M A N TEMP T E M P TIMER...
  • Page 10 OWNER’S Using the Remote Control INFORMATION TEMP T E M P TEMP T E M P...
  • Page 11 OWNER’S Using the Remote Control INFORMATION...
  • Page 12 OWNER’S Using the Remote Control INFORMATION...
  • Page 13: Kits & Accessories

    OWNER’S Kits & Accessories INFORMATION Required Kits Information accurate at the time of printing and subject to change without notice. Fuel Beds (choose one) 530LSK Traditional Logs & Reversible Liners Set 530RSK Rocks & Reversible Liners Set 530CSK Coals & Reversible Liners Set 530DWK Driftwood &...
  • Page 14: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 15: Servicing & Maintenance

    OWNER’S Servicing & Maintenance INFORMATION Servicing Your Fireplace We recommend having your fi replace serviced every year. Contact your supplier quoting the model number. It will be helpful if the appliance’s serial number can also be quoted. These numbers are on the information card.
  • Page 16: Cleaning Your Fireplace

    OWNER’S Servicing & Maintenance INFORMATION Cleaning Your Fireplace Clean the window panes following the guidelines in this section. WARNING Clean the steel trim with mild soap and warm water. DO NOT TOUCH THE GLASS WHILE IT IS HOT! Any alcohol/solvent base cleaner will weaken the coat- Let the fi...
  • Page 17 Damage caused by incorrect window installa- tion is not covered by the Valor warranty. 6. Apply fi rm hand pressure around the window frame to ensure the window is sealed tight against the fi rebox.
  • Page 18: Checking Pilot And Burner Flames

    OWNER’S Servicing & Maintenance INFORMATION Checking Pilot and Burner Flames The appliance area must always be kept clear and free from combustible materials, gasoline and other A periodic check of the pilot and burner fl ames should fl ammable vapors and liquids. Inspect the vent terminal be made.
  • Page 19: Replacing Batteries

    OWNER’S Servicing & Maintenance INFORMATION Replacing Batteries 2. Slide and remove the receiver cover. 3. Replace batteries with 4 AA alkaline batteries. WARNING 4. Replace the cover. DO NOT ATTEMPT TO CHANGE THE BATTER- 5. Put the receiver back in its position pushing IES WHILE THE FIREPLACE IS STILL HOT! Let it in so it attaches to the Velcro tab.
  • Page 20: Specifi Cations

    QUALIFIED Specifi cations INSTALLER Approvals and Codes The supply pressure must be between the limits shown in the Ratings table on the previous page. This appliance is certifi ed to ANSI Z21.88–2016/CSA The supply connection is 3/8 inch NPT female located at 2.33–2016 American National Standard/CSA Standard the left side of the control valve.
  • Page 21: Dimensions, Clearance And Framing

    QUALIFIED Dimensions, Clearance and Framing INSTALLER The dimensions, clearances and framing vary with WARNING each applications and with the front trim installed. Refer to the installation instructions of the front trim chosen Some materials or items, although safe, for more information. may discolor, shrink, warp, crack, peel, and Non-Combustible Materials Specifi...
  • Page 22 QUALIFIED Venting INSTALLER Wall Thickness Co-Linear Direct Vent Installations for Free Standing or Recessed Installations (fl exible The appliance vent is suitable for penetrating a com- piping) bustible wall up to 14 inches (36 cm) thick. A non-combustible wall can be any thickness up to the Converts the appliance outlet collars to accept two maximum horizontal run of vent pipe allowed for the 3-inch diameter fl...
  • Page 23: Co-Axial Venting

    QUALIFIED Co-Axial Venting INSTALLER Typical Co-Axial Venting Components See venting accessories list on pages 46–47 for allowable components. VERTICAL TERMINATION STORM COLLAR FLASHING ATTIC INSULATION SHIELD HORIZONTAL 2-PIECE TERMINATION ATTIC WALL FIRESTOP THIMBLE PIPE CEILING LENGTH FIRESTOP 90˚ ELBOW PIPE LENGTH PIPE LENGTH...
  • Page 24 QUALIFIED Co-Axial Venting INSTALLER Rear Vent with No Vertical Rise 14” (36 cm) max. within combustible wall. 12” (30 cm) 26” (66 cm) max. max vent pipe vent length Use 658TG of 845TG vent guard with a vent terminal located at less than 7’...
  • Page 25 QUALIFIED Co-Axial Venting INSTALLER Horizontal Vent Termination Location or a safety hazard. Local codes or regulations may require greater clearances. • The vent terminal must be located on an outside • The vent terminal must not be recessed into a wall wall or through the roof.
  • Page 26 QUALIFIED Co-Axial Venting INSTALLER Co-Axial Venting Confi gurations with Vertical Rise 4 x 90º ELBOWS MAXIMUM (or equivalent) 3” min. above top of horizontal pipe 1” min. all around vertical pipe 1” min. around bottom & sides of horizontal pipe Use 658TG or 845TG vent guard with a...
  • Page 27 QUALIFIED Co-Axial Venting INSTALLER How to Read the Venting Chart 5. Each 90 degrees elbow installed on the horizontal plane is equivalent to a 3 feet horizontal pipe; The chart below applies to co-axial roof or wall therefore, 3 feet must be subtracted from allowable termination in installations with vertical rise.
  • Page 28 QUALIFIED Co-Axial Venting INSTALLER Attaching Air Restrictors—Appliances with Vertical Vent Rise Only Air Restrictor No restrictors are required for appliances which only have a horizontal vent run. If installing an appliance which has a rear vent outlet connection and no vertical vent pipe rise, ignore this stage.
  • Page 29 QUALIFIED Co-Axial Venting INSTALLER Co-Axial Vertical Installations Overhang should • Check the roof pitch to determine which roof not extend beyond vent if within 48” of fl ashing will be needed. See venting accessories list Horizontal termination cap on pages 46–47 for allowable components. overhang •...
  • Page 30: Co-Linear Venting

    QUALIFIED Co-Linear Venting INSTALLER Co-linear Venting into Existing Solid-Fuel 556CLA Burning Fireplaces and Chimneys 2 x 3” liners 2 x 3” 3/4” liners See venting accessories list on pages 46–47 for allowable components. 3/4” Co-linear adapter may be installed as top or rear 556CLA outlet—see page 33.
  • Page 31: Installation Planning

    QUALIFIED Co-Linear Venting INSTALLER 10” 10” 7-5/8” dia. collar 3” Inlet & Exhaust Front Rear Collars 559CLT Co-Linear Vertical Ter- 559FSK Flashing Kit 720SWK Sidewall Horizontal Terminal minal —for logs or rocks units only Alternate to 556CLA/559CLT/559FSK Conversion for vertical termination Co-Linear to Co-Axial Adapter Flashing...
  • Page 32: Installation

    QUALIFIED Installation INSTALLER Unpack Appliance Convert from Rear Outlet to Top Outlet (co-axial venting) Beware of sharp edges! Wear gloves! If installing with rear vent outlet, go to next step. 1. Remove the cardboard wrapping and the wood pallet from the appliance and discard. 1.
  • Page 33: Prepare Vent Outlet

    QUALIFIED Installation INSTALLER Prepare Vent Outlet Co-linear Installations using Valor 556CLA Co-linear Adapter Co-axial Installations (Note: Instructions may vary as 556CLA may be in- 1. Fit the adapter 817VAK over stalled on Top or Back of Heater.) the appliance vent collars 1.
  • Page 34: Connect Gas Supply

    QUALIFIED Installation INSTALLER Connect Gas Supply • When testing for leaks: • It’s preferable to rough-in the gas line at this point before proceeding with the fi rebox installation. • Make sure that the appliance is turned off . • The appliance is supplied for supply gas connection •...
  • Page 35: Install Ceramic Liners (Logs Or Coals Only)

    QUALIFIED Installation INSTALLER Install Ceramic Liners (Logs or Coals only) The 530LSK and CSK fuel beds include a set of reversible liners. One side shows the brick pattern and the reverse side shows a black vertical fl uted pattern. Follow the instructions below to install the liner set on the chosen side.
  • Page 36: Install The 530Lsk-Traditional Logs Set

    QUALIFIED Installation INSTALLER Install the 530LSK—Traditional Logs Set 5. Locate the left side log on the ceramic pin on the left 1. Place the base log on the supports in the fi rebox hand side of the base log. Rest the narrow nose of and against the support at the fi...
  • Page 37: Install The 530Csk-Coal Set

    QUALIFIED Installation INSTALLER Install the 530CSK—Coal Set 1. Place the base coal on the supports in the fi rebox 4. The center right coal has letter “R” embossed and against the fi rebox back. underneath. Place this coal behind the front 2.
  • Page 38: Install The 530Rsk-Rock Set And Liners

    QUALIFIED Installation INSTALLER Install the 530RSK—Rock Set and Liners Install rock base & platform 1. Place the rock base behind the burner. The two Unpack each piece of the ceramic rock set carefully to protrusions in front of the base should rest on the avoid damages.
  • Page 39 QUALIFIED Installation INSTALLER Rock Other Position in the Top row rear Description markers fi rebox Top far left 1 peg under Top row rear Top left 1 peg under Top row rear Top right 1 peg under Top row rear Top far right 1 peg under Top row rear...
  • Page 40: Install The 530Dwk-Driftwood Kit And Liners

    QUALIFIED Installation INSTALLER Install the 530DWK—Driftwood Kit and Liners Install platform, driftwood logs and pebbles 1. Place the protrusion at the back of the base log on Unpack each piece of the ceramic driftwood set the ledge of the rear panel support as far back as carefully to avoid damages.
  • Page 41 QUALIFIED Installation INSTALLER 3. Place the rear log on top of the base log locating it 6. Place the left log inserting the platform peg into the into the notches on top of the base log. hole at the end of the log; rest the upper end of the log in the notch on the rear log as indicated.
  • Page 42: Refi T And Check Window

    fi replace, damage components, cause overheating resulting in dangerous conditions. Damage caused by incorrect window installa- tion is not covered by the Valor warranty. 5. Apply fi rm hand pressure around the window frame to ensure the window is sealed tight against the fi...
  • Page 43: Synchronize Remote Control

    QUALIFIED Installation INSTALLER Synchronize Remote Control The receiver and the handset of the remote control sys- tem must be initially synchronized before the fi rst use. 1. Insert alkaline batteries in the remote control receiver and handset. The receiver is located left of the control valve under the burner module.
  • Page 44: Install Front, Trim And Barrier Screen

    QUALIFIED Installation INSTALLER Install Front, Trim and Barrier Screen Install the front chosen by the customer for the fi replace. Install as well the barrier screen which is provided with the front or trim. Show the customer how to access the controls when the front or trim are installed and how to remove them the front or trim.
  • Page 45: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Optional Wall Switch Kit 1265WSK Connector Yellow GV60 Wiring Diagram...
  • Page 46: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER...
  • Page 47 QUALIFIED Approved Venting Components INSTALLER...
  • Page 48: Commonwealth Of Massachusetts

    QUALIFIED Commonwealth of Massachusetts INSTALLER State of Massachusetts Carbon Monoxide 3. SIGNAGE. A metal or plastic identifi cation plate shall be permanently mounted to the exterior of the Detector/Vent Terminal Signage building at a minimum height of eight (8) feet above Requirements grade directly in line with the exhaust vent terminal for For all side wall horizontally vented gas fueled...
  • Page 49 QUALIFIED Commonwealth of Massachusetts INSTALLER (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi...
  • Page 50: Warranty

    The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase. Alternatively, the warranty registration form may be fi lled out online at www.valorfi replaces.com. b) Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation instructions.
  • Page 51: Replacement Parts

    OWNER’S Replacement Parts INFORMATION Description Part no. Description Part no. Side wall support (2) 330A898 44a Ignition cable sleeve 4002244 Rear wall support 320B320 Receiver G6R-R3AM-ZV (CP) 4001911 Velcro strip 4000022 Handset G6R H3T5-ZV (BJ) 4001910 Port cover 4000828AH Wall mount holder 9000008 Inner vent collar 340B174...
  • Page 52 OWNER’S Replacement Parts INFORMATION Description Part no. Driftwood Kit 530DWK Log Set (including pebbles) 4005603 Base log 4005887 Rear log 4005888 Left log 4005889 Right log 4005890 Centre log 4005891 Brown beach pebble 4003082 Small grey beach pebble 4003086 Grey beach pebble 4003083 Small beige beach pebble 4003087...
  • Page 53 OWNER’S Replacement Parts INFORMATION Natural gas Propane gas 43a, 43b 530CSK 530LSK...
  • Page 54 OWNER’S Replacement Parts INFORMATION 530RSK 530DWK...
  • Page 55 Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 56 Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

Portrait 530ip

Table of Contents