3.1 Approvals & codes
This appliance is certified by International Approval Services for use in Canada and the USA.
The appliance complies with CGA P.4.1, Testing method for measuring annual fireplace efficiencies.
The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code, ANSI
Z223.1or the Canadian installation code CAN/CGA-149. Only qualified licensed or trained personnel should install the
appliance.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

3.2 Ratings

Altitude (Ft)
Input Max. (Btu/h)
Input Min (Btu/h)
Manifold pressure (in.w.c.)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
*Tested to CAN/CGA - 2.17 Gas fired appliances for use at high altitudes. In the USA installations may require deration over
2000ft - Check local codes.

3.3 Wall Thickness

The appliance vent is suitable for penetrating a combustible wall up to 14" (36cm) thick.
A non-combustible wall can be any thickness up to the maximum horizontal run of vent pipe allowed for the particular
installation – See sections 4 and 5.

3.4 Supply Gas

Heater engine 530XAN /XCN is used on Natural gas installations.
Heater engine 530XAP/XCP is used on Propane installations.
The supply pressure must be between the limits shown in section 3.2 above.
3
The supply connection is
/
8
The opening for the gas supply line is at the rear left corner of the appliance.

3.5 Controls

The unit is supplied standard with a battery operated, hand held remote control and receiver which has the ability to adjust the
gas input of the unit between the pilot setting and the maximum input .The pilot light must be manually lit at the valve and
may be left on or turned off with each use. The remote control provides full thermostatic or manual operation with the option
of programming thermostat function between certain times of the day. Manual operation of the valve is also possible should
the batteries or remote control fail.

3.6 Electrical

The unit does not require an electrical power source unless fitted with an optional circulating fan.

3.0 GENERAL

Nat. Gas
LPG
0-4500 *
20,500
19,000
6,000
11,600
3.5 – 3.9
10.3 – 10.7
5.0
11.0
10.5
14.0
''NPT.