Valor 530XAN Installation And Owner's Manual page 20

Direct vent gas fireplace heater
Table of Contents

Advertisement

5.5.3 Rear vent connection, vertical vent rise
with horizontal termination (all fronts)
(Fig. 30)
Can be used with either #551DVK standard vent kit another
terminal cap and accessories.
Adapter #817VAK, two 90° vent elbows and pipe lengths
will be required.
(See venting options section of this manual).
No more than two 90°elbows must be used.
Minimum
A: From floor to top of
vent duct
D: Vertical pipe run
12in (30cm)
E: Horizontal pipe run
(Total before and after
elbows)
F: Clearance to
2
combustible materials
above horizontal pipe
run
5
G: Clearance to
1
combustible materials
below horizontal pipe
run
5
H: Clearance to
1
combustible materials
all round vertical pipe
run and at sides of
horizontal pipe run
5.5.4 Rear vent connection, vertical vent rise with horizontal snorkel termination ( all fronts)
For "semi-basement" situations where snorkel accessory alone does not raise termination sufficiently above ground level.
The dimensional requirements in section 5.5.3 and figure 30 apply.
Adapter #817VAK, two 90° vent
elbows, pipe lengths and a snorkel
termination will be required.
A wall thimble kit may also be
necessary.
(See venting options section of this
manual).
No more than two 90°elbows must be
used.
5.5.5 Corner location,
horizontal vent run only,
(all fronts) (Fig. 31)
Can be used with either #551DVK
standard vent kit another terminal cap
and accessories.
Adapter #817VAK and 45° elbow will
be required.
(See venting options section of this
manual).
Maximum
7
7
3ft 7
/
"
10ft 7
/
"
8
8
(111cm)
(325cm)
8ft (244cm)
-
4ft 6in
(137cm)
5
/
" (6.7cm)
-
8
/
" (3.3cm)
-
16
/
" (3.3cm)
-
16
Figure 31
Figure 30
20 of 50