Valor PORTRAIT 530INI Installation & Owner's Manual

Direct vent gas insert fireplace
Hide thumbs Also See for PORTRAIT 530INI:

Advertisement

Direct Vent Gas Insert Fireplace
DANGER
!
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk
individuals.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
▪ Do not try to light any appliance.
▪ Do not touch any electrical switch; do
not use any phone in your building.
▪ Leave the building immediately.
▪ Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
▪ If you cannot reach your gas supplier,
call the fi re department.
— Installation and service must be
performed by a qualifi ed installer, service
agency or the gas supplier.
4005323-01
©2016, Miles Industries Ltd. All rights reserved.
P
ORTRAIT
530INI (NG) & 530IPI (LPG)
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the EN-
GINE ONLY. A front trim kit is REQUIRED to install
the engine as it affects the framing cavity and posi-
tion of the engine. A barrier screen is provided with
the front or trim kit. Refer to the manual supplied
with the front for framing and fi nishing.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PORTRAIT 530INI and is the answer not in the manual?

Questions and answers

Summary of Contents for Valor PORTRAIT 530INI

  • Page 1 ORTRAIT Direct Vent Gas Insert Fireplace 530INI (NG) & 530IPI (LPG) Installation & Owner’s Manual DANGER I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2016. All rights reserved.
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully Due to the high temperature, the appliance should be before starting the installation. FAILURE TO FOLLOW LOCATED out of traffi c areas and away from furniture these installation instructions may result in possible fi re and draperies.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, A physical barrier is strongly • recommended if there are young Parts of your Valor Fireplace become • children, or at-risk individuals in the extremely hot while in operation. house. Install an approved after- The glass viewing window •...
  • Page 5: Owner's Information

    For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages is fully tested during the production process for your 3 and 4 of this manual BEFORE operating safety and comfort.
  • Page 6: Cleaning Your Fireplace

    OWNER’S Owner’s Information INFORMATION Cleaning Your Fireplace To remove the window for cleaning: WARNING 1. Unhook the front and barrier DO NOT TOUCH THE GLASS WHILE IT IS HOT! screen. Let the fi replace cool fi rst before cleaning it. 2.
  • Page 7: Checking Pilot And Burner Flames

    Damage caused by incorrect window installa- With Rocks tion is not covered by the Valor warranty. Correct fl ame appearance 7. If the Hot Glass Warning plate has been removed from the front lower corner of the window,...
  • Page 8: Replacing Batteries

    OWNER’S Owner’s Information INFORMATION Replacing Batteries Servicing Your Fireplace If your appliance require any attention, contact your WARNING supplier quoting the model number. It will be helpful if the appliance serial number can also be quoted. This is DO NOT ATTEMPT TO CHANGE THE BATTER- on the rating plate located under the fi...
  • Page 9: How To Turn Your Fireplace Off (Including Pilot)

    OWNER’S Owner’s Information INFORMATION How to Turn Your Fireplace OFF (including pilot) How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently Familiarize yourself with each of these methods before operating your fi replace. You can use one of the two following methods to ensure that your fi...
  • Page 10: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system IMPORTANT: BEFORE YOU BEGIN, please note that for the fi rst time, the receiver and the handset must on this system, the settings of time, temperature and be synchronized. See the sub-section Set-up Remote automatic ON/OFF can only be programmed when Control on page 36 of this manual.
  • Page 11 OWNER’S Remote Control Operation INFORMATION • Press and hold (small fl ame) MODES OF OPERATION button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” TEMPERA- SETTING THE “DAYTIME” TEMPERATURE TURE Default Settings: (sun), 23ºC / 74ºF Default Settings: (moon), “ ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 13 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 14 OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ 6:00 a.m.— ☼ ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 15: Options

    OWNER’S Options INFORMATION Required Kits Fuel Beds (choose one) 530LSK Logs & Reversible Liners Set 530RSK Rocks & Reversible Liners Set 530CSK Coals & Reversible Liners Set Fronts (choose one) Barrier Screen Number 536CXBI President Insert Front (closure plate 582 or 583 required) 4003359 539/549/550 only )
  • Page 16: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 17: Specifi Cations

    QUALIFIED Specifi cations INSTALLER Approvals and Codes Supply Gas This appliance is certifi ed to ANSI Z21.88–2014/CSA Heater engine 530INI is used for natural gas insert 2.33–2014 American National Standard/CSA Standard installations. for Vented Gas Fireplace Heaters for use in Canada Heater engine 530IPI is used for propane gas insert and USA.
  • Page 18 QUALIFIED Overview INSTALLER This appliance may ONLY be installed in an existing unaltered, functioning solid-fuel burning fi replace with a working fl ue and constructed of non-combustible material. DO NOT install into combustible construction. This appliance is NOT APPROVED for installation with a zero clearance kit. WARNING WARNING Chimney Terminal Cap...
  • Page 19: Overview

    QUALIFIED Overview INSTALLER Venting Options Rear view Note: 536/541/563 fronts require a closure plate (582/583CPB) to ensure proper positioning of casting. Other fronts are supplied with a backing plate included. Co-linear appliance, as supplied (2 x 3” diameter liners) 530INI/IPI as supplied 530INI/IPI with 720SWK—Sidewall Kit Co-linear installation into existing F/P Sidewall co-linear installation into existing F/P...
  • Page 20 QUALIFIED Overview INSTALLER Venting Options 530INI/IPI with 530CVA—Co-axial Vent Adapter Co-linear installation into existing F/P Rear view Approved co-axial 530CVA termination or approved co-axial 4-3/4 x 3 to 6-5/8 x 4 adapter + approved Flashing co-axial 6-5/8 x 4 4-3/4 x 3” 3”...
  • Page 21: Dimensions

    QUALIFIED Dimensions INSTALLER 20” 9” - 11-1/2” depending on front trim - see front installation manual See Front trims installation 2 x 3” dia. manuals for dimensions colinear 4-3/4”x 3” dia. vent co-axial adaptor Ensure base of heater is flush* with finished hearth height, otherwise front will not fit.
  • Page 22: Clearances

    QUALIFIED Clearances INSTALLER WARNING WARNING Some materials or items, although safe, may discolor, shrink, warp, crack, peel, and so on because of the heat produced by the fi replace. Avoid placing candles, paintings, photos, and other items sensitive to heat around the fi replace. Mantel Combustible Mantel Clearances Depth...
  • Page 23: Venting

    QUALIFIED Venting INSTALLER Typical Vent Installation Terminal See the Approved Venting Components list on page 39 of this manual. Flashing Vent Location The vent terminal must be located through the roof. This direct vent appliance is designed to operate when an undisturbed airfl...
  • Page 24: Attaching Air Restrictors

    QUALIFIED Venting INSTALLER Attaching Air Restrictors Air Restrictor Two restrictor sets, like the one shown right, are supplied with each 530 engine unit. The restrictors cover part of the inlet air openings in the fi rebox rear wall on each side of the brick support. Do NOT install the restrictors in the roof of the fi...
  • Page 25: Installation Planning

    QUALIFIED Installation Planning INSTALLER Installer—READ THIS FIRST Only qualifi ed licensed or trained personnel 7. Place the appliance in fi nal position. should install this appliance. 8. Install the venting system. 9. Position the restrictors. 1. YOU NEED TO KNOW FROM THE HOMEOWNER: 10.
  • Page 26: Installation

    QUALIFIED Existing Fireplace Preparation INSTALLER Gas Line Routing Combustible Mantels Plan the routing of the gas line before proceeding. Combustible mantel clearances should conform to Utilize the existing hole for the gas line. If the factory- those required for the original solid-fuel fi replace into built fi...
  • Page 27: Remove Window

    QUALIFIED Installation INSTALLER Remove Window 1. Release the top of the window by pulling forward the two levers at the top corners. 2. Unscrew the two spring-loaded bolts securing the bottom of the window. 3. Carefully lift the window. Keep the window and bolts in a safe place.
  • Page 28: Connect Venting

    QUALIFIED Installation INSTALLER Connect Venting IMPORTANT: This appliance’s venting system is room sealed and therefore, does not require room air to be used in the combustion process. 1. Rough-in two 3” diameter vent liners into the existing chimney system from the roof. Be careful not to tear or damage the liners in the process.
  • Page 29: Connect Gas Supply

    QUALIFIED Installation INSTALLER Connect Gas Supply • When testing for leaks: • It’s preferable to rough-in the gas line at this point before proceeding with the fi rebox installation. • Make sure that the appliance is turned off. • The appliance is supplied for supply gas connection •...
  • Page 30: Install Ceramic Liners (Logs Or Coals Only)

    QUALIFIED Installation INSTALLER Install Ceramic Liners (Logs or Coals only) The 530LSK and CSK fuel beds include a set of 1. Locate the ceramic rear wall in the channel at back reversible liners. One side shows the brick pattern and of the fi...
  • Page 31: Install The 530Lsk-Logs Set

    QUALIFIED Installation INSTALLER Install the 530LSK—Logs Set 5. Locate the left side log on the ceramic pin on the left 1. Place the base log on the supports in the fi rebox hand side of the base log. Rest the narrow nose of and against the support at the fi...
  • Page 32: Install The 530Csk-Coal Set

    QUALIFIED Installation INSTALLER Install the 530CSK—Coal Set 1. Place the base coal on the supports in the fi rebox 4. The center right coal has letter “R” embossed and against the fi rebox back. underneath. Place this coal behind the front right 2.
  • Page 33: Install The 530Rsk-Rock Set And Liners

    QUALIFIED Installation INSTALLER Install the 530RSK—Rock Set and Liners Install rock base & platform 1. Place the rock base behind the burner. The two Unpack each piece of the ceramic rock set carefully to protrusions in front of the base should rest on the avoid damages.
  • Page 34 QUALIFIED Installation INSTALLER Rock Other Position in the Top row rear Description markers fi rebox Top far left 1 peg under Top row rear Top left 1 peg under Top row rear Top right 1 peg under Top row rear Top far right 1 peg under Top row rear...
  • Page 35: Refi T And Check Window

    Damage caused by incorrect window installa- tion is not covered by the Valor warranty. 7. If the Hot Glass Warning plate has been removed 3. Fit the two spring loaded bolts through the bottom of...
  • Page 36: Set-Up Remote Control

    QUALIFIED Installation INSTALLER Set-up Remote Control The receiver and the handset of the remote control sys- tem must be initially synchronized before the fi rst use. 1. Insert alkaline batteries in the remote control receiver and handset. The receiver is located left of the control valve under the burner module.
  • Page 37: Install Front Trim And Barrier Screen

    QUALIFIED Installation INSTALLER Install Front Trim and Barrier Screen Install the front chosen by the customer for the fi replace. Install as well the barrier screen which is provided with the front trim. Show the customer how to access the controls when the front is installed and how to remove the front.
  • Page 38: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Optional Wall Switch Kit 1265WSK Connector Yellow GV60 Wiring Diagram...
  • Page 39: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 530INI/IPI insert engine ONLY Venting Parts Code / availability by Manufacturer Venting Parts Description 4DVC 940264 HSDV4658- Standard Co-axial 46DVA-VC 4DT-VC TM-4VT — 4DH-1313 559CAT 940364 1313 940206LP...
  • Page 40: Warranty

    The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase. Alternatively, the warranty registration form may be fi lled out online at www.valorfi replaces.com. b) Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation instructions.
  • Page 41: Replacement Parts

    OWNER’S Replacement Parts INFORMATION Code Description Part no. Code Description Part no. Side wall support (2) 330A898 Ceramic coals & liners set 530CSK Rear wall support 320B320 Ceramic coal set 000B245 Velcro strip 4000022 Centre left coal 640K615 Port cover 4000828AH Base coal 650K237...
  • Page 42 OWNER’S Replacement Parts INFORMATION 33a, 33b...
  • Page 43 OWNER’S Replacement Parts INFORMATION 530CSK 530LSK 530RSK...
  • Page 45 Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 46 Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

Portrait 530ipi

Table of Contents