Error Message
TIMING PULSE
ERROR
VOLTAGE ERROR
NOT INITIALIZED
COMMUNICATION
ERROR
VALIDATION
ERROR
Cause
Error occurred on motor Replace the motor
Error occurred on motor
circuit
Wiring between
connector and motor is
wrong
Error occurred on power
supply (24V)
Error occurred on power
supply (24V)
Error occurred on
solenoid control
Printer is not initialized
Error occurred on the
printer communication
Error occurred on
validation V unit
Wiring error occurred
on microswitch of
validation V unit
Chapter 4: Setup 4-71
Possible Remedies
Replace the circuit
Connect the wire
Replace the main
processor board or
power supply
Replace the main
processor board or
power supply
Replace the solenoid
(for paper feed, stamp,
knife)
Initialize the printer
Connect the printer
interface cable
Replace validation V
unit
Connect the wire