  • Page 1 NCR 7448 Workstation Release 1.3 Site Preparation B005-0000-1201 Issue D...
  • Page 2 NCR, therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.
  • Page 3 Safety Warnings The NCR 7448 Workstation must be connected to an AC outlet that is near the workstation and is easily accessible by the operator. Warning: This unit contains hazardous voltages and should only be serviced by qualified service personnel.
  • Page 4 ii Site Preparation Fuse Replacement Caution: For continued protection against risk of fire, replace only with the same type and ratings of fuse. Attention: Pour prévenir et vous protéger contre un risque de feu, remplacer la fusible avec une autre fusible de même type, seulement. Power Supply Cord Used as Disconnect Means Caution: The power supply cord is used as the main disconnect device.
  • Page 5 Mettre au rébut les batteries usagées conformément aux instructions du fabricant. Peripheral Usage The NCR 7448 Workstation should only be used with peripheral devices which are certified by the appropriate safety agency for the country of installation (UL, CSA, TUV, VDE) or those which are recommended by NCR Corporation.
  • Page 6 Contain Nickel-Cadmium battery. Must be recycled or disposed of properly. About this Book This book provides site preparation information for NCR 7448 Workstation components. Peripheral component and AC wiring site preparation information is NOT provided in this book. The associated reference documents are listed in...
  • Page 7: Table Of Contents

    Site Preparation v Table of Contents NCR 7448 SITE PREPARATION NCR 7448 SITE PREPARATION ........ NCR 7448 SITE PREPARATION NCR 7448 SITE PREPARATION ........................................1 1 1 1 ........ 7448 W ........... 2...
  • Page 8 vi Site Preparation Peripheral Tray, and 2182 Cash Drawer ..........16 Configuration with 2 x 20 Operator Display, 80-Key Keyboard and 1- Line Numeric Customer Display............17 Configuration with 2 x 20 Operator Display, 176-Key Micromotion Keyboard and International VFD Customer Display with Telescope Mount ......................
  • Page 9 Site Preparation vii ................41 ABLE LLUSTRATIONS ENVIRONMENTAL REQUIREMENTS ........ ENVIRONMENTAL REQUIREMENTS ................ 44 ENVIRONMENTAL REQUIREMENTS ENVIRONMENTAL REQUIREMENTS ...................................... 44 AROMETRIC RESSURE ..................... 44 EMPERATURE ....................44 UMIDITY APPENDIX A: TRANSIENT PROTECTION APPENDIX A: TRANSIENT PROTECTION ........ APPENDIX A: TRANSIENT PROTECTION APPENDIX A: TRANSIENT PROTECTION ........
  • Page 10 viii Site Preparation Revision Record Issue Date Remarks August 2000 First Issue December 2000 Update for Release 1.1 March 2001 Update for Release 1.2 December 2001 Update for Release 1.3...
  • Page 11 NCR. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The user is cautioned that changes or modifications not expressly approved by NCR may void the user’s authority to operate the equipment.
  • Page 13: Ncr 7448 Site Preparation

    The NCR 7448 Workstation system consists of separate pieces that may be combined in a variety of configurations. Typical configurations are shown in the next section.
  • Page 14: Typical 7448 Workstation Configurations

    2 Site Preparation Typical 7448 Workstation Configurations The following illustrations show 7448 Workstation components arranged in typical configurations. Dimensions and operating clearances are listed in the 7448 Dimensions section to identify the space required by each configuration. Use the component drawings in this book and associated peripheral documentation to determine the operating space requirements for your site.
  • Page 15 Site Preparation 3 7448 Workstation with 80-Key Conventional Keyboard...
  • Page 16: Interpreting The Model Number

    4 Site Preparation Interpreting the Model Number NCR Model 7448 - XX XX - XX XX Class Number Language Code Major Model Code Power Code Sub Model Code...
  • Page 17: Related Site Preparation Data

    Related Site Preparation Data AC Power and Communications Wiring Title Order Number NCR Ethernet Communications Wiring Guide BST0-2118-82 NCR Workstation and Peripherals AC Wiring Guide BST0-2115-53 Peripherals Title Order Number 7140 Receipt/ Journal Printer User’s Guide B005-0000-1001 7158 Thermal Receipt and Impact Slip Printer B005-0000-1112 Owner’s Guide...
  • Page 18: How To Order

    Information Products are available through several different channels. You need an order form if you are using fax, e-mail, or mail order. Order forms available to NCR personnel through QuickLook. In QuickLook, click on Forms & Templates, then select Information Products Order Form.
  • Page 19 Site Preparation 7 SMTP • Order, Management UnitedK (International) Mail Order • NCR Corporation IPP-Dayton 1700 S. Paterson Boulevard Dayton, OH 45479 • NCR Corporation 915 High Road North Finchley London N12 ONH United Kingdom...
  • Page 20: Customer Responsibilities

    Provide and install floor coverings and environment systems that limit or control static electricity build-up and discharge In general, keep the NCR equipment area free from dust, smoke, lint, and other particles. Restrict smoking, eating, and drinking around the equipment. Avoid location the equipment near other machines that generate ink, carbon, and paper dust particles.
  • Page 21: Store Wiring Requirements

    AC Wiring The customer must provide suitable AC power for the terminals, associated equipment, and devices. An AC power circuit dedicated to the NCR equipment installation is recommended. The AC outlet must be installed near the terminal and easily accessible to the operator.
  • Page 22: System Configuration Diagram

    10 Site Preparation System Configuration Diagram Passive Color LCD TFT Color LCD 2x20 Operator Mono LCD Display RS232 CRT Operator Display 7448 Base Unit 80 key Keyboard 176 key Keyboard 2182 Compact Mid-Range Cash Cash Drawer Drawer PS/2 Keyboard Drawer RS232 Customer Displays 1 line 10 digit 4x20 char.
  • Page 23: Physical Considerations

    • Do not lift by the display. • The NCR 7448 Workstation does not attach to the drawer unit and may slide off if the drawer unit is tipped.
  • Page 24: Operating And Service Clearance Requirements

    12 Site Preparation Operating and Service Clearance Requirements Service Clearance Requirements All Units Device Above Left Side Right Side Front Behind mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) All Units 153 (6) 153 (6) 202 (8) Operating Clearance Requirements Device Above Left Side...
  • Page 25: Workstation Dimensions

    Site Preparation 13 Workstation Dimensions Configuration with 2x20 Operator Display, 80key keyboard, 1-Line Numeric Customer Display, Peripheral Tray, and 2182 Cash Drawer...
  • Page 26: Configuration With Mono/Passive Color Lcd Operator Display, 80Key

    14 Site Preparation Configuration with Mono/Passive Color LCD Operator Display, 80key keyboard, International VFD Customer Display with Telescope Mount, Peripheral Tray, and 2182 Cash Drawer...
  • Page 27: Configuration With Tft Color Lcd Operator Display, 80Key Keyboard, International Vfd Customer Display With Telescope Mount, Peripheral Tray, And 2182 Cash Drawer

    Site Preparation 15 Configuration with TFT Color LCD Operator Display, 80key keyboard, International VFD Customer Display with Telescope Mount, Peripheral Tray, and 2182 Cash Drawer...
  • Page 28: Configuration With 9" Crt Operator Display, 80Key Keyboard

    16 Site Preparation Configuration with 9” CRT Operator Display, 80key keyboard, Peripheral Tray, and 2182 Cash Drawer 598 mm 465 mm 151 mm 450 mm 475 mm 400 mm 18 mm 437 mm...
  • Page 29: Configuration With 2 X 20 Operator Display, 80-Key Keyboard And 1-Line Numeric Customer Display

    Site Preparation 17 Configuration with 2 x 20 Operator Display, 80-Key Keyboard and 1-Line Numeric Customer Display...
  • Page 30: Mount

    18 Site Preparation Configuration with 2 x 20 Operator Display, 176-Key Micromotion Keyboard and International VFD Customer Display with Telescope Mount...
  • Page 31: Configuration With Mono/Passive Color Lcd Operator Display, 80-Key Keyboard And International Vfd Customer Display With Telescope Mount

    Site Preparation 19 Configuration with Mono/Passive Color LCD Operator Display, 80-Key Keyboard and International VFD Customer Display with Telescope Mount...
  • Page 32: Configuration With

    20 Site Preparation Configuration with TFT LCD Display, 80key keyboard, International VFD Customer Display with Telescope Mount...
  • Page 33: Configuration With Lcd Operator Display, 176-Key Micromotion Keyboard And International Vfd Customer Display With Telescope Mount

    Site Preparation 21 Configuration with LCD Operator Display, 176-Key Micromotion Keyboard and International VFD Customer Display with Telescope Mount...
  • Page 34: Configuration With

    22 Site Preparation Configuration with TFT Color LCD Display, 176-Key Micromotion keyboard and International VFD Customer Display with Telescope Mount...
  • Page 35: Component Dimensions

    Site Preparation 23 Component Dimensions Base Unit with 2 x 20 Operator Display and 80-key Conventional Keyboard...
  • Page 36: Base Unit With 10.4" Mono/Passive Color Lcd Operator Display With 176-Key Micromotion Keyboard

    24 Site Preparation Base Unit with 10.4” Mono/Passive Color LCD Operator Display with 176-Key Micromotion Keyboard...
  • Page 37: Base Unit With Tft Color Operator Lcd Display And 176-Key Micromotion Keyboard

    Site Preparation 25 Base Unit with TFT Color Operator LCD Display and 176- Key Micromotion keyboard...
  • Page 38: Base Unit With 9" Crt Operator Display And 80-Key Conventional Keyboard

    26 Site Preparation Base Unit with 9” CRT Operator Display and 80-key Conventional Keyboard 355 mm 372 mm 495 mm...
  • Page 39 Site Preparation 27 245 mm...
  • Page 40: Cash Drawer

    28 Site Preparation Cash Drawer NCR 2260 Cash Drawer 457 mm (18 in.) 121 mm (4.75 in.) 457 mm (18 in.) 277 mm (11 in.) Operating and Service Clearance 15414 for Drawer NCR 2189 Cash Drawer 464 mm (18.25 in.) 133 mm (5.25 in.)
  • Page 41 Site Preparation 29 NCR 2182 Cash Drawer...
  • Page 42: Customer Displays

    30 Site Preparation Customer Displays NCR 1-Line Numeric Customer Display integrated with Telescope Mount/ Low Profile Mount NCR 4-Line Alpha Numeric Customer Display integrated with Telescope Mount/ Low Profile Mount Low Profile Mount 224 mm Telescope Mount 344 mm or 419 mm...
  • Page 43 Site Preparation 31 NCR International VFD Customer Display integrated with Telescope Mount/ Low Profile Mount Low Profile Mount 229 mm Telescope Mount 349mm or 424 mm...
  • Page 44: Printers

    32 Site Preparation Printers 7140 Printer 206 mm 8.12 in. 273 mm 10.75 in. 170 mm 245 mm 6.7 in. 9.65 in. 150 mm 5.9 in. 15457 7158 Printer 165 mm (6.50 in.) 305 mm (12.00 in.) 336 mm 229 mm (9.00 in) (13.25 in) 17307...
  • Page 45 Site Preparation 33 7161 Printer 148 mm (5.5 in.) 240 mm 165 mm (9.45 in.) (6.5 in.) 7194 Printer 212 mm 130 mm (8.3 in.) (5.10 in.) 85 mm (3.30 in.) 157 mm (6.20 in.) 187 mm (7.4 in.) 16492...
  • Page 46 34 Site Preparation 7196 Printer 146 mm 254 mm 108 mm (5.75 in.) (10.00 in.) (4.25 in.) 140 m (5.50 in.) 17306...
  • Page 47: Component Weights

    Site Preparation 35 Component Weights The following table shows the component weights for each integrated workstation component. Workstation Components Weight lbs. Base Unit- Flash Disk Model* Base Unit- Hard Disk Model** 7.94 2189 Cash Drawer 20.9 2182 Cash Drawer 13.7 6.23 2260 Cash Drawer 22.7...
  • Page 48 36 Site Preparation *Note: Base Unit- Flash Disk Model, includes the Lower Cabinet, Upper Cabinet, Chassis with MediaGX Processor Board, Personality Board, and PCMCIA Expansion Board, AC Adapter, Printer AC Adapter and NiCad Battery. **Note: Base Unit- Hard Disk Model, includes the Lower Cabinet, Upper Cabinet, Chassis with MediaGX Processor Board, Personality Board, and PCMCIA Expansion Board, 3.2 inch Hard Disk Drive, AC Adapter and Core-Ferrite for Flat Cable.
  • Page 49: Power Requirements

    Site Preparation 37 Power Requirements The 7448 Workstation base unit contains 100 - 240 volt AC Adapters for a printer and a workstation. The AC Adapter for a workstation provides power for up to four of the peripherals. The following tables show operating specifications for the power supply. The AC power cable plugs in at the back of the base unit.
  • Page 50: Cable Routing Considerations

    Type1 and Type2 Usable Cable Lengths The usable (external) length of all 7448 Workstation cables is less than the total length, because a portion of the cable remains inside the base unit when connected. The usable length can also vary according to the configuration of the components.
  • Page 51: System Cables

    Site Preparation 39 System Cables Cable Type Cable Name NCR Part No./ Corp. Approximate ID No. Cable Lengths Cash Drawer Drawer Extension Cable 230-0145735 3 m/ 9.8 ft 1424-C112-0030 Dual Cash Drawer, Y-Cable 497-0409394 0.6 m/ 25 in. 1416-C372-0006 Power U.S./Canada Power Cord...
  • Page 52 40 Site Preparation Cable Type Cable Name NCR Part No./ Corp. Approximate ID No. Cable Lengths Printer For 7161 Printer or 7194 497-0411815 4 m/ 13 ft Extender Drop Printer 1416-C417-0040 Cables (7453-K641) Serial For 7161 Printer 497-0411816 4 m/ 13 ft...
  • Page 53: Cable Illustrations

    Site Preparation 41 Cable Illustrations 7870, 7875, or 7880 Scanner/Scale (RS-232) Modular D-Shell 10-Pin 9-Pin 497-0300422 Plug Receptacle To 7448 Scanner RS-232 Port 7890 Presentation Scanner Cables 497-0405826 497-0410036 Scanner Module Cable 7890 Scanner Interface Cable To 7890 To 7448 Scanner Workstation 497-0300132 (JAPAN)
  • Page 54 42 Site Preparation Dual Cash Drawer, Y-Cable Cash DWR. #1 497-0409394 Cash DWR. #2 Coin Dispenser Cable 25-pin 9-pin 497-0404832 - 4 m D-Shell D-shell Plug Receptacle To 7448 Coin RS-232Port Dispenser Printer Interface Cables 7158, 7194, 7140 Printers 9-pin 9-pin D-shell D-shell...
  • Page 55 497-0407427 - 1 m 25-pin 9-pin 497-0407429 - 4 m D-Shell D-shell Plug 497-0407430 - 15.2 m Receptacle To 7448 Printer RS-232Port NCR 7194 Printer with 7453-K641 Cable Extender 9-pin 25-pin 25-pin 9-pin D-shell D-shell D-shell D-shell Receptacle Plug Receptacle...
  • Page 56: Environmental Requirements

    Operating range of pressure: 105kPa to 79.5 kPa Temperature The 7448 Workstation is designed to operate over the temperature ranges shown below. Continuous operation must be avoided, however, at or near the temperature extremes or in locations where the temperature changes beyond the temperature restrictions.
  • Page 57 Site Preparation 45...
  • Page 59: Appendix A: Transient Protection

    Such transient energy can be very damaging to electronic hardware, and can also cause data corruption. Under these circumstances, NCR recommends the use of AC power transient suppressors. Such protection devices are intended to guard against power line transients that can result in hardware damage and various system or program errors.
  • Page 60 A-2 Appendix A: Transient Protection • Upon failure, exhibit a positive indication of its failure such as a blown fuse or tripped breaker. • Be listed by the accepted safety organization for the country involved (UL, CSA, VDE, ETL, and so on) and the installation must conform to local, state, and national electrical codes and regulations.
  • Page 61: Data Line Transient Protection

    Be installed in accordance with all applicable local, state, and national electrical codes and regulation. Note: In certain countries, NCR is able to supply both power and data line transient suppressors as well as a comprehensive line of power conditioning equipment.