CDM-600L Satellite Modem
Front Panel Operation
6.3.4.6
MONITOR: LNB
LNB:
The monitor display shows the measured LNB current load and LNB voltage at the receive
IF connector.
6.3.4.7
MONITOR:BUC
BUC:CURRENT = 0000mA VOLT = 47.9V CLASS = N/A
PWR = N/A Amb = N/A PLL = N/A
CURRENT
VOLT
CLASS
PWR
Amb
PLL
VER
CURRENT = xxx mA
If a BUC supply is installed, displays measured BUC load current.
If a BUC supply is installed, displays measured BUC supply voltage at the
TX-IF connector.
If BUC FSK is enabled, displays the output power rating of the BUC.
If BUC FSK is enabled, displays the output power as measured by the BUC
power monitor.
If BUC FSK is enabled, displays BUC ambient temperature in °C.
If BUC FSK is enabled, displays the fault status of the BUC PLL
synthesizers.
If BUC FSK is enabled, displays the M&C software version of the BUC.
6–38
Voltage = xx V
VER = NA
Revision 2