7. Service Mode

7.11.3 Constant Light Output (Optional)

The CLO menu item will be greyed out when this option is not installed.
What can be done?
In a multichannel setup, due to tolerances on the lamps and optical components (e.g. lenses), or due to the different positions of
the projectors in relation to the screen, there will always be a difference in light output between the projectors.
Within this menu it is possible to track and maintain the brightness level of each projector, the projector will deliver a Constant Light
Output = CLO.
How to set up a CLO system?
CLO levels in Multichannel setups are controlled through RS232 by e.g. the xRACU™ Master Control Unit.
Overview of the CLO menu
Following 'Adjustable' parameters are available in the CLO menu:
Tracking Interval: this parameter will determine the time between each Light Measurement.
Following Tracking Intervals are available:
-
8s
-
16s
-
32s
-
64s
-
128s
Target Light Value: this parameter will set the desired Constant Light Output Value.
Following parameters can be consulted to start up or maintain a setup with projectors running in CLO mode:
light value: this parameter will display the current Light Output Value measured by the Light Sensor.
tracking in range: CLO is running in optimal conditions when this parameter indicates [YES].
measuring in range: CLO is running in optimal conditions when this parameter indicates [YES].
How to use the CLO menu?
1. Push the cursor key ↑ or ↓ to highlight CLO. (menu 7-27)
2. Press ENTER to select.
The CLO menu will be displayed.
3. Push the cursor key ↑ or ↓ to highlight Target Light Value and press ENTER to select. (menu 7-28)
4. Use the cursor keys ← or → in combination with the numeric keys to enter the Target Light Value, e.g. 8000, and press ENTER
to confirm.
5. Push the cursor key ↑ or ↓ to highlight Tracking Interval and press ENTER to select. (menu 7-29)
6. Use the cursor keys ← or → to select the desired Tracking Interval, e.g. 16s, and press ENTER to activate. (menu 7-30)
Note: The Motorized Dimming menu item is greyed out when CLO is active.
DIMMING
LAMP DIMMING
MOTORIZED DIMMING
CLO
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 7-27
126
CONSTANT LIGHT OUTPUT
TRACKING INTERVAL [OFF]
TARGET LIGHT VALUE 8000
_______________________
STATUS
light value 931
tracking in range [YES]
meas.
in range [YES]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 7-28
CONSTANT LIGHT OUTPUT
TRACKING INTERVAL [OFF]
TARGET LIGHT VALUE 8000
_______________________
STATUS
light value 931
tracking in range [YES]
meas.
in range [YES]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 7-29
R5976420 BARCOREALITY SIM 6 ULTRA 14052003
CONSTANT LIGHT OUTPUT
TRACKING INTERVAL [16s]
TARGET LIGHT VALUE 8000
_______________________
STATUS
light value 931
tracking in range [YES]
meas.
in range [YES]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return