5. Random Access
How to install the correct settings for the options in the Edit file menu.
EDIT FILE OPTIONS
Source number
Clamp delay
Clamp width
Field polarity
Select with ↑ or ↓
<ENTER> to toggle
↑ or ↓ to change value
<EXIT> to return
Menu 5-11
Source number
Clamp delay
Clamp width
Sync
pulse
Clamp
pulse
Image 5-1
Example for Clamp position [trailing]
Field polarity
40
1
0
10
[pos]
The source number of a non-active source can be changed to any other source number. This makes
it possible to create a file for future source numbers.
The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be
any value between 0 and 255. Change the value by pushing the cursor key ↑ or ↓.
The width of the clamp pulse can be any value between 0 and 255. Change the value by pushing
the cursor key ↑ or ↓.
Clamp
Clamp
delay
width
The field polarity function is used for interlaced images. Both rasters of the image could be shifted in a
wrong way (double lines are visible in the image). This can be corrected by forcing the field polarity to
[neg] or [pos]. Use the ENTER key to toggle between [pos] and [neg].
R5976420 BARCOREALITY SIM 6 ULTRA 14052003