7. Service Mode
How to Initialize the Black Uniformity settings?
1. Push the cursor key ↑ or ↓ to highlight Initialize Black. (menu 7-37)
2. Press ENTER to Initialize the Black Uniformity settings.
UNIFORMITY
ADJUST GRAY
ADJUST BLACK
ADJUST WHITE
DEFAULT
INITIALIZE WHITE
INITIALIZE BLACK
Select with ↑ or ↓
<ENTER> to toggle/select
<EXIT> to return
Menu 7-37

7.13 Electronic convergence

What can be done ?
The electronic convergence allows to correct some convergence errors by shifting horizontally an integral amount of pixels (-3,-2,-
1,0,+1,+2,+3), the adjustment is possible on the three colors.
To avoid color distortion when not necessary leave the electronic convergence settings with a neutral value
for the three colors (+0)
How to adjust the convergence ?
1. Push the cursor key ↑ or ↓ to highlight Electronic convergence. (menu 7-38)
2. Press ENTER to select.
The Electronic Convergence slider box is displayed. (image 7-5)
3. Push the cursor key ↑ or ↓ to select the desired color.
4. Push the cursor key ← or → to adjust the convergence (Range in pixels: –3 to +3)
5. Press EXIT to return to the Service Mode menu.
SERVICE
UNIFORMITY
ELECTRONIC CONVERGENCE
DYNACOLOR
GRAY LEVEL DEFINITION
PURITY
DISPLAY BLANKING
PANEL ADJUSTMENT
PRESET INPUT BALANCE
MORE...
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 7-38
CONVERGENCE RED
Image 7-5
Electronic Convergence slider box
130
0
R5976420 BARCOREALITY SIM 6 ULTRA 14052003

Advertisement

Table of Contents
loading

This manual is also suitable for:

Barcoreality sim 6 ultra r9040151

Table of Contents