2. Basic Commands
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (Answer)
Start
Projector address
Command[0]
Command[1]
Data [0]
Data [1]
Checksum
Stop
2.30.5 Lamp runtime, Read
Description
Reads the lamp runtime, the lamp (lamp1 or lamp2) runtime to be read is given in the data field.
Command
Command [0]
Data
Data[0] = unsigned byte:
data value: 1 = lamp1 ; 2 = lamp2
Returned Data
Data[0] = unsigned byte (1 = lamp1 ; 2 = lamp2)
unsigned double word (4 bytes) representing the runitme : see chapter "1. Serial communications Basics", "Data words", page 6
Data[1] = msb
Data[2]
Data[3]
Data[4] = lsb
2.30.6 Lamps Serial number, Read
Description
Reads the Lamps Serial number, the lamp (lamp1 or lamp2) to be read is given in the data field.
66
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x0d
\x00
\x1e
\x4d
\xff
\x64