Alarm Output; External Analog Input Disconnection Detection - Omron 3G3JX User Manual

Sysdrive jx series compact simplified inverters
Hide thumbs Also See for 3G3JX:
Table of Contents

Advertisement

•C044 can be set from 0 to 100. The setting corresponds to the range of 0 to the maximum target
value.
C044
C044

Alarm Output

This is output when the Inverter trips. If you use the relay for alarm outputs, set and check
operation,, as the SPDT contact is used for the terminals. For details, refer to the description of the
relay output, "Multi-function Output Terminal ON Delay/OFF Delay" (page 4-70).
Data
Symbol
05
AL
Available input terminals
Required settings

External Analog Input Disconnection Detection

•Outputs a signal if an error is detected in the external analog inputs (FV, FI).
Data
Symbol
06
Dc
Available input terminals
Required settings
Feedback value
OD
ON
Operation
Error
Trip
Alarm output
Function name
Alarm output
Function name
Disconnection detection
Target value
ON
STOP
RESET
RUN
Stop
STOP
RESET
Error
Status
ON
The Inverter is in trip status.
OFF
The Inverter is normal.
P1-PC, MA-MC (or MB-MC)
C021, C026
Status
ON
The Inverter is in trip status.
OFF
The Inverter is normal.
P1-PC, MA-MC (or MB-MC)
C021, C026, A001, A005
4-2 Function Mode
Description
Description
4-66
4