Front Panel Configuration Switches; Using The Nti Keemux-Usbv-Xu Kvm Switch - Network Technologies KEEMUX-USBV-xU Installation & User Manual

Usb kvm switch
Table of Contents

Advertisement

Front Panel Configuration Switches

Table 1 * (default settings)
Switch
STAND-ALONE SWITCH
SLAVE
MASTER W/4-PORT SLAVES
MASTER W/8-PORT SLAVES
MASTER W/16-PORT SLAVES
Table 2 * (default settings) Master & Slave dip switch 2-4 Settings
SW2
SW3
SW4
OFF*
OFF*
OFF*
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
SLAVE #2 (KEEMUX-USBV-8U)
NTI
R
NETWORK TECHNOLOGIES INCORPORATED
V
V
V
V
I
I
I
I
D
D
D
D
E
E
E
E
O
O
O
O
8
7
6
5
CPU 8
CPU 7
CPU 6
CPU 5
CPU 4

USING THE NTI KEEMUX-USBV-xU KVM SWITCH

Control over the CPUs attached to the NTI KEEMUX-USBV-xU KVM switch is achieved through operation of the KEEMUX-USBV-
xU KVM switch. Once the KEEMUX-USBV-xU KVM switch is properly connected, the KEEMUX-USBV-xU KVM switch will enable
a connection to be made between the CPUs attached to its VIDEO-x and CPU-x ports and the monitor and input devices
attached to the MONITOR and USB DEVICES ports. The LEDs on the control panel of the KEEMUX-USBV-xU KVM switch will
illuminate depending on which port (and subsequent associated CPU) is being connected the monitor and input devices. The
choice of which CPU the monitor and input devices will be connected to is determined by controlling the KEEMUX-USBV-xU KVM
switch either through the front control panel on the KEEMUX-USBV-xU KVM switch, by keyboard control, or by optional methods
such as RS232, Infrared, or an On Screen Display (OSD).
SW1
SW5
SW6
OFF*
OFF*
OFF*
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
Master with-
Slave Setting
No Slave Attached
N/A
1 Slave attached
Slave #1
2 Slaves attached
Slave #2
3 Slaves attached
Slave #3
4 Slaves attached
Slave #4
5 Slaves attached
Slave #5
6 Slaves attached
Slave #6
7 Slaves attached
Slave #7
8 Slaves attached
Slave #8
Fig. 7
MASTER (KEEMUX-USBV-8U)
NTI
R
NETWORK TECHNOLOGIES INCORPORATED
V
V
V
I
I
I
D
D
D
E
E
E
O
O
O
7
6
8
CPU 8
CPU 7
CPU 6
CPU 5
VEXT-xx-MM
1275 Danner Drive, Aurora Ohio 44202
330-562-7070
www.nti1.com
M
V
V
V
V
O
I
I
I
I
N
D
D
D
D
I
E
E
E
E
T
5VDC
O
O
O
O
O
2A
4
3
2
1
R
USB
DEVICES
CPU 3
CPU 2
CPU 1
-
+
These switch settings (Table 2) enable the slave
to establish its identity (i.e. location in the group)
to the Master.
Side Note: In a Master, the same switches are
used to configure the Master for how many slaves
are attached to it.
1275 Danner Drive, Aurora Ohio 44202
330-562-7070
www.nti1.com
M
V
V
V
V
V
O
I
I
I
I
I
N
D
D
D
D
D
I
E
E
E
E
E
T
5VDC
O
O
O
O
O
O
2A
5
4
3
2
1
R
USB
DEVICES
CPU 4
CPU 3
CPU 2
CPU 1
-
+
SLAVE #1 (KEEMUX-USBV-8U)
NTI
R
NETWORK TECHNOLOGIES INCORPORATED
CPU 8
USB-AB-xxM
7
VEXT-xx-MM
1275 Danner Drive, Aurora Ohio 44202
330-562-7070
www.nti1.com
M
V
V
V
V
V
V
V
V
O
I
I
I
I
I
I
I
I
N
D
D
D
D
D
D
D
D
I
E
E
E
E
E
E
E
E
T
O
O
O
O
O
O
O
O
O
8
7
6
5
4
3
2
1
R
USB
DEVICES
CPU 7
CPU 6
CPU 5
CPU 4
CPU 3
CPU 2
CPU 1
5VDC
2A
-
+

Advertisement

Table of Contents
loading

Table of Contents