SpectraLink NetLink e340 Configuration And Administration Manual page 36

Wireless telephones with session initiation protocol (sip)
Hide thumbs Also See for NetLink e340:
Table of Contents

Advertisement

SpectraLink Corporation
The generic file (sip_allusers.cfg)
The generic configuration file provides system information common to all handsets.
The handset files (e.g. sip_JohnDoe.cfg)
The handset configuration file provides specific information for the handset to
identify itself and communicate to other phones. Each handset must have its own
file with a unique filename. Use the same parameters as the generic file when
programming the handset files:
Use the following parameters when programming the configuration files:
Parameter
Value
PROXYn_ADDR
xxx.xxx.xxx.xxx:pppp
or
proxyname:pppp
PROXYn _DOMAIN
Domain name
PROXYn_TYPE
Inter-Tel
SER
Asterisk
PROXYn_KEYPRESS_2833 enable
disable
PROXYn_KEYPRESS_INFO
enable
disable
PROXYn_HOLD_IP0
enable
disable
PROXYn _MAIL_SUBSCR
name@xxx.xxx.xxx.xxx
or
sip:name@domain
PROXYn_MAIL_ACCESS
name@xxx.xxx.xxx.xxx
or
sip:name@domain
For mail notifications, in general you will need to define only one contact parameter for each proxy. If the
2
proxy server automatically creates and renews subscriptions when the handset registers, then only the
PROXYn _MAIL_NOTIFY contact need be specified. If the handset must subscribe to a particular contact to
get mail notification, then only the PROXYn_MAIL_SUBSCR contact needs to be specified.
PN: 72-1089-02-E.doc
Configuration and Administration—NetLink e340/h340/i640 Wireless Telephone
Description
Proxy address.
Domain served by this proxy
server.
Specify the manufacturer of
each defined proxy server.
Controls generation of in-
stream RFC2833 formatted
key press events.
Controls generation of SIP
INFO requests to the SIP
server for keypress events.
Controls setting of the
media stream IP destination
address to 0 (zero) when a
call is put on hold.
Contact to whom the
handset should subscribe
for mail notification.
Contact to whom the
handset should invite to
access the mail center.
with SIP
Notes
n = 1, 2, 3
xxx.xxx.xxx.xxx = IP4 address
pppp = port (optional, 5060 is the default)
proxyname = computer name (DHCP only)
n = 1, 2, 3
DOMAIN = [example: spectralink.com]
Can be omitted if the proxy does not act as a
domain server.
Used by the handset to perform proxy-
specific actions based on known behavior for
specific proxy types. Only the three shown
values may be used. Omit this parameter if
the value is not one of these recognized
settings.
n = 1, 2, 3
n = 1, 2, 3
n = 1, 2, 3
Use for compatibility with older SIP servers
that may not recognize newer stream
attribute parameters for HOLD status.
n = 1, 2, 3
name = mail server contact name.
xxx.xxx.xxx.xxx = IP4 address.
Domain where the mail resides
See above.