SpectraLink  1725-36143-001 Interface Manual

SpectraLink 1725-36143-001 Interface Manual

Polycom wireless telephones linkplus interface guide

Advertisement

Quick Links

Siemens Hicom/HiPath optiset
LinkPlus Interface Guide
for SpectraLink e340/h340/i640
Wireless Telephones
July 2008 Edition
1725-36143-001
Version K

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SpectraLink 1725-36143-001 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SpectraLink SpectraLink 1725-36143-001

  • Page 1 Siemens Hicom/HiPath optiset LinkPlus Interface Guide for SpectraLink e340/h340/i640 Wireless Telephones July 2008 Edition 1725-36143-001 Version K...
  • Page 2 Polycom, Inc. has prepared this document for use by Polycom personnel and customers. The drawings and specifications contained herein are the property of Polycom and shall be neither reproduced in whole or in part without the prior written approval of Polycom, nor be implied to grant any license to make, use, or sell equipment manufactured in accordance herewith.
  • Page 3: About This Guide

    About This Guide Polycom is the market leader in multi-cellular wireless telephone systems for the workplace. We manufacture a range of products to suit any size installation. SpectraLink 8000 Telephony Gateway uses our LinkPlus digital integration technology to integrate with various digital switch platforms.
  • Page 4: Customer Support

    LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLink e340/h340/i640 Wireless Telephones Customer Support Polycom wants you to have a successful installation. If you have questions please contact the Customer Support Hotline at (800) 775-5330. The hotline is open Monday through Friday, 6 a.m.
  • Page 5: Plan The Interface

    Plan the Interface The system administrator programs the telephone system for use with the SpectraLink 8000 System using the normal administration terminal or procedures. Programming can be done after the handsets are registered. Recommended programming includes assigning extension numbers to the handsets and programming features on the telephone system so they are easily accessible from the handsets.
  • Page 6: Programmable Feature Keys

    LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLink e340/h340/i640 Wireless Telephones handsets, which line or lines should ring at which handset; and which line will be selected when the user goes off-hook. Programmable feature keys The handsets support programmable keys as shown in the key-map diagrams below.
  • Page 7 The SpectraLink Wireless Telephone SpectraLink e340 Wireless Telephone The handset has a pixel-based alphanumeric display (up to 4-line x 16-character), plus line and status indicators. The user can toggle between two display views in order to see all 24 possible characters per line sent by the Hicom CS.
  • Page 8 LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLink e340/h340/i640 Wireless Telephones Certain characters may be used by the Hicom CS that are not implemented in the handset. Flashing characters are not implemented on the handset, nor is rolling or scrolling of text. Although the optiset E Basic telephone does not have a display, any display information sent by the Hicom CS will be displayed on the handset.
  • Page 9: Handset Modes

    Handset Modes Standby(on-hook) In the standby mode the handset is waiting for an incoming call or for the user to place an outgoing call. The extension number is shown on the display and there is no dial tone. In this mode, the handset is conserving battery power and bandwidth.
  • Page 10: Feature Programming Requirements

    LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLink e340/h340/i640 Wireless Telephones LED emulation When Lines are programmed as shown on the key-map diagrams, the numeral icons on the handset display will be mapped to the LEDs associated with the corresponding Feature Keys. The line icons will be displayed as follows: Feature Programming Requirements When planning the interface, the following information must be taken...
  • Page 11 Plan the Interface have their corresponding menu items display on the handset function menu. See the key-map diagram for the function keys that are available for feature programming. Hold The Hold feature may be programmed to a softkey as shown in the softkey programming table so that the Hold function is available on the handset.
  • Page 12: Speed Dial

    LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLink e340/h340/i640 Wireless Telephones OptiGuide menu The OptiGuide menu provides access to features appropriate to the current context of the handset. You may navigate through the menus by using the default programming: (Select), programmed to the softkeys as described in the following section.
  • Page 13: Button Programming

    Plan the Interface Hicom 300/HiPath 4000 Phone Test access code The Hicom 300/HiPath 4000 Phone Test (access code*940) will not work on the SpectraLink e340/h340/i640 Wireless Telephones. Button programming For the Hicom 150/HiPath 3000, phone button programming (access code *91) will not work. All button programming must be done by the administrator and not the user.
  • Page 15: Interface Implementation

    Interface Implementation This section describes the recommended programming to use the SpectraLink 8000 Telephony Gateway with the Siemens Hicom 150/ HiPath 3000 E and 300 E/H Communications Server (CS). The procedures assume: • • Set the Switch Interface Type Connect to the SpectraLink 8000 Telephony Gateway using the serial or modem interface.
  • Page 16 LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLink e340/h340/i640 Wireless Telephones Level Siemens optiset Diagrams The diagrams on these pages illustrate additional features that may be programmed to softkeys and shortcut keys. Siemens optiset E Standard - Hicom 300/HiPath 4000 Key-mapping Softkey Shortcut Menu Label...
  • Page 17 The FCN and LINE labels represent the key sequence on the handset mapped to the corresponding key on the optiset E. The feature labels to the right of the keys represent one possible mapping scheme, but any feature may be programmed to keys that do not have setup restrictions described in the Programming Requirements section.
  • Page 18 LinkPlus Interface Guide: Siemens Hicom/HiPath optiset for SpectraLink e340/h340/i640 Wireless Telephones Siemens optiset E Basic - Hicom 150/HiPath 3000 Key-mapping The FCN and LINE labels represent the key sequence on the handset mapped to the corresponding key on the optiset E. The feature labels to the right of the keys represent one possible mapping scheme, but any feature may be programmed to keys that do not have setup restrictions described in the Programming Requirements section.
  • Page 19 The handset function menu has these default settings: PN: 1725-36143-001_K.doc 0 = Select 2 = Voicemail (corresponds to the Mailbox feature key above) * = Previous # = Next Interface Implementation...
  • Page 21: Extension Assignments Worksheet

    Extension Assignments Worksheet Shelf: _______ Interface Module: _______ Handset # Ext. # Handset 1 Handset 2 Handset 3 Handset 4 Handset 5 Handset 6 Handset 7 Handset 8 Handset 9 Handset 10 Handset 11 Handset 12 Handset 13 Handset 14 Handset 15 Handset 16 PN: 1725-36143-001_K.doc...