SpectraLink Corporation
Message
Description
Erasing Memory
Handset has determined that a download
should occur and is erasing the current
software from memory.
Files Too Big
Handset software download files are
incorrect or corrupted.
Flash Config Error
Handset internal configuration is corrupt.
Initializing ...
The handset is performing power-on
initialization.
Internal Err. # #
The handset has detected a fault from which
it cannot recover.
Multiple GW Res
More than one NetLink SVP Server has
responded.
Multiple SVP Reg
y...y = SVP IP address
yyy.yyy.yyy.yyy
Handset received responses from multiple
SVP Servers; displays IP address of one
responding SVP Server.
Must Upgrade SW!
Handset software is incompatible with
hardware.
Net Busy
x...x = AP MAC address.
xxxxxxxxxxxx
Handset cannot obtain sufficient bandwidth
to support a call; displays MAC of failing AP.
No DHCP Server
Handset is unable to contact the DHCP
server.
No ESSID
Attempted to run Site Survey application
without an ESSID set.
No Func Code
Handset software download files are
incorrect or corrupted.
No Host IP
The handset is configured for "static IP" (as
opposed to "use DHCP") and no valid host IP
address (the handset's IP address) has been
entered.
PN: 72-1089-02-E.doc
Configuration and Administration—NetLink e340/h340/i640 Wireless Telephone
Action
None. When the progress bar fills the
display line the erase operation is
complete.
Do not turn the handset off during this
operation.
Download new software from the
Software
SpectraLink website per
Maintenance
.
Perform "Restore Defaults" operation via
administrator menus (or re-program with
Configuration Cradle).
None. This is informational only.
Record the error code so it can be
reported.
Turn the handset off then on again.
If error persists, try registering a different
handset to this telephone port.
If error still persists, contact SpectraLink
Technical Support and report the error.
Caused by two or more handsets sharing
the same IP address. Assign unique IP
addresses to each handset.
This can happen if the handset has been
reconfigured to use a different SVP server
and then powered up before the previous
server has had time to determine that the
handset is no longer connected to it. The
problem should go away after about 30
seconds.
Download new software from the
Software
SpectraLink website per
Maintenance
.
Try the call again later.
Check that DNCP is operational and
connected to WLAN or use Static IP
configuration in the handset.
Let handset come completely up.
Statically configure an ESSID in the Admin
menu.
Reconfigure the handset to gain access to
the WLAN and download new code.
Enter a valid IP address in the
configuration settings or change to "use
DHCP."
with SIP