Millivolt Board Removal / Installation - kozy heat SP-36 SLIM PROFILE 36"DIRECT VENT GAS FIREPLACE Installation & Operating Manual

Slim profile 36" direct vent gas fireplace
Table of Contents

Advertisement

(N) MILLIVOLT BOARD REMOVAL / INSTALLATION
NOTE: The fireplace is equipped with the millivolt board & burner/cover assembly already in position. The
millivolt board and burner cover assembly must be secured in place using the nuts supplied with the
fireplace. Follow instructions 'INSTALLING THE BOARD' on page #25 to properly secure the board and
burner/cover assembly in place. Follow these procedures should the millivolt board need replacing or is
removed for servicing.
MILLIVOLT BOARD REMOVAL.
1. Turn the control knob to 'OFF'.
2. Shut off the gas supply at the manual shut-off valve.
3. Disconnect gas line flex tube from the manual shut-off valve.
4. Disconnect any wall switch, remote control or thermostat wires from the valve.
5. Remove the upper grill, glass assembly and logs.
6 5 . Loosen and remove the (2) 1/4" nuts securing the burner cover, Figure 17.
7. Remove the burner / cover assembly by lifting the front up and sliding it off the burner orifice.
Figure 17
8. Remove the pilot shield and set aside. Figure 18A.
9. Loosen and remove the (7) 1/4" nuts securing the millivolt board
and, while grasping the board, gently lift it off the (7) bolts and
remove from the firebox. Figure 18B.
Figure 18B
1/4" NUTS SECURING BURNER COVER
(
7) 1/4" nuts securing millivolt board
Figure 18A
Page 24
Pilot Shield