Replacing The Fuser Oil Roller - MINOLTA-QMS 2200 User Manual

Magicolor desklaser
Hide thumbs Also See for 2200:
Table of Contents

Advertisement

10
Check the status message in the message window.
If a transfer roller alert message is displayed, use the Service/Clear care menu to
remove it.

Replacing the Fuser Oil Roller

The fuser oil roller provides a lubricant for the printer via an oil-impregnated roller. This
oil is necessary for the proper functioning of the printer.
WARNING!
The fuser unit is hot. When the top cover is opened, the fuser unit temperature
drops gradually (one hour wait time). Do not replace the fuser oil roller until you
are sure that the fuser unit has cooled down.
When the fuser oil roller is worn out, the message "REPLACE OIL ROLLER" appears
and the printer does not print. Replace the fuser oil roller.
1
Turn off the printer.
2
Open the printer's top cover.
3
Rotate the two fuser oil roller lock levers to
release the fuser oil roller.
Dispose of it properly according to your local
regulations.
4
Remove the new fuser oil roller from its
shipping box.
Attention
If you set the new fuser oil roller on a table, do not allow the roller surface to
contact the table or get dirty. This could lower image quality.
24
Replacing the Fuser Oil Roller