Symptom
Cause
Irregular
The media is moist from
print or mot-
humidity.
tled image
appears.
There is
The media is moist from
insufficient
humidity.
fusing or the
Media with specifications not
image comes
covered by the printer war-
off when
ranty is being used.
rubbed.
Your media type may be
incorrectly set.
The print or
The toner cartridges or the
color density
OPC drum may be near
may be
empty or damaged.
uneven.
The OPC drum may be
misinstalled or defective.
Solving Problems with Printing Quality
Solution
Remove the moist media and replace it with dry media.
Remove the moist media and replace it with dry media.
Use media that is covered by the printer warranty.
Envelopes, glossy stock, labels, transfer media, and thick
stock have to be set in the Thick Stock mode.
Remove the toner cartridges and gently rock them five or
six times to redistribute the toner. Then, reinstall the
cartridges.
Install new toner cartridges.
Reinstall the OPC drum cartridge. If necessary, replace the
entire drum kit.