Table 3-6.
9000-A2-GB33-20
Health and Status Messages (2 of 7)
Message
CTS down to Port-1 Device
DBM BRI Card Failed
(ISDN BRI DBM only)
DBM Download Required
(ISDN BRI DBM only)
DCLB Active, [Interface]
DLCI nnnn Down,
frame relay link
DSL Line Training Alarm at
Network 1
DTE External LB Active, Port-n
DTE Init. Ext LB Active, Port-n
DTPLB Active, Port-2
DTR Down from Port-1 Device
EER at ISDN PRI (Active/Idle)
(ISDN PRI DBM only)
EER at Network 1
Ethernet Mgmt Down
Ethernet Port Down
May 2003
What It Indicates
The user data port CTS control lead on the iMarc unit
is off.
One or more of the access unit's integrated circuit
chips has failed to internally loop data through the
dial backup unit BRI circuit.
A download attempt was interrupted and failed to
complete.
The NAM software and DBM software are
incompatible.
A V.54 Loopback is active on the specified interface.
The DLCI for the specified frame relay link is down.
The DSL interface is training.
A Data Terminal Loopback is running on the
specified user data port.
The DTE has initiated an external DTE Loopback on
the specified user data port.
A Data Terminal Payload Loopback (DTPLB) is
active on the synchronous user data port.
The DTR control lead from the device connected to
the user data port is deasserted.
The error rate of the received ISDN network signal
exceeds the currently configured threshold. This
condition only occurs if the network interface is
configured for ESF framing and a PRI dial backup
module (DBM) is installed.
Active – Backup call was in progress.
Idle – DBM was in Idle mode.
This condition clears when the error rate falls below
the threshold value, which may take up to
15 minutes.
The error rate of the received network signal
exceeds the currently configured threshold. This
condition only occurs if the network interface is
configured for ESF framing.
This condition clears when the error rate falls below
the threshold value, which may take up to
15 minutes.
The Ethernet port is enabled, but communication
between the management system and the unit is not
currently possible on the port.
The Ethernet data link is down.