Paradyne FrameSaver SLV 9128 Installation Instructions Manual

1-slot unit
Hide thumbs Also See for FrameSaver SLV 9128:

Advertisement

Quick Links

FrameSaver SLV 9128/9128-II
1-Slot Unit
Installation Instructions
Document Number 9128-A2-GN12-20
September 2000
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select Library
Select the following document:
9128-A2-GB20
FrameSaver SLV, Models 9126, 9128, and 9128-II, User's Guide
To order a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
Package Checklist
Verify that your package contains the following:
FrameSaver SLV unit
Power cord with desktop 120 VAC power transformer.
T1 network cable
ISDN PRI or BRI cable, if applicable
FrameSaver SLV 9128/9128-II Quick Reference (Document No. 9128-A2-GL10)
Be sure to register your warranty at www.paradyne.com/warranty.
Technical Manuals
FrameSaver Frame Relay Devices.
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne FrameSaver SLV 9128

  • Page 1 We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain competitive prices for our products. Complete documentation for this product is available at www.paradyne.com. Select Library Technical Manuals FrameSaver Frame Relay Devices.
  • Page 2: Before You Begin

    Before You Begin Make sure you have: A dedicated, grounded power outlet that is protected by a circuit breaker within 6 feet of the FrameSaver SLV (service level verifier) unit. A clean, well-lit, and ventilated site that is free from environmental extremes. One-to-two feet of clearance for cable connections.
  • Page 3: Safety Instructions

    Safety Instructions Read the Important Safety Instructions beginning on page 25. Installing the Power Supply and Cord 1. Insert the power supply’s 4-prong plug into the POWER jack. When inserting the plug at the rear of the FrameSaver unit, align the plug with the notch above the POWER jack.
  • Page 4: Connecting The Com Port To An Asynchronous Terminal

    Connecting the COM Port to an Asynchronous Terminal A VT100-compatible asynchronous terminal or a PC providing VT100 terminal emulation must be used to set up access to and management of the unit. 1. Configure the terminal or PC to be compatible with the FrameSaver unit: –...
  • Page 5: A Quick Guide To Configuration

    A Quick Guide to Configuration The FrameSaver unit should operate using the default (factory-set) configuration options, with exception to the changes specified in these installation instructions. Refer to the following table for help in navigating the menus. Press the . . . To .
  • Page 6: About The Installation Procedures

    About the Installation Procedures There are two methods for installing and setting up the FrameSaver unit. One person can install and set up the unit. If this is the case, see Full Installation and Setup . An installer can physically install and set up access to the unit, and the network operation center (NOC) can complete the setup.
  • Page 7 Dedicated Network Management Link on? prompt, which will be used by the NOC to access the unit. 5. For a FrameSaver SLV 9128-II that will use its Ethernet port, select the Ethernet Port Options Screen and configure the following: – Enable Interface Status. If the NMS will be on a different subnet than the unit, enter Yes at the Would you like to set the Node’s Default IP...
  • Page 8 20. If the unit is equipped with an ISDN DBM, install the ISDN DBM cable (see Connecting the ISDN on page 22). 21. If the FrameSaver SLV 9128-II will use its Ethernet port for management, install the Ethernet cable (see Connecting to the Ethernet on page 23).
  • Page 9: Minimal Installation For Service Providers

    5. If the unit is equipped with an ISDN DBM, install the ISDN DBM cable (see Connecting to the ISDN on page 22). 6. If a FrameSaver SLV 9128-II will use its Ethernet port for management, install the Ethernet cable (see Connecting to the Ethernet on page 23).
  • Page 10 Installing and Setting Up a Model 9128-II in Leased Line Mode It is assumed that frame relay service may not be available at the site and the unit will be set up in Leased Line mode. 1. Select the Easy Install feature. Main Menu Easy Install 2.
  • Page 11 Completing Setup of the Unit From the NOC 1. Access the remote FrameSaver unit. – For a unit installed using the procedure in Physically Installing the Unit and Setting Up for Remote Access on page 9 , access the unit using the dedicated management link, using the Node IP Address that was entered.
  • Page 12: Setting Up Local Management At The Central Site

    Setting Up Local Management at the Central Site 1. Create a DLCI for the data port. Configuration Data Ports DLCI Records 2. Save the configuration. 3. Create a Management PVC using the data port DLCI just created. Configuration Management and Communication Management PVC Minimally, enter the following options: –...
  • Page 13: Setting Up The Modem

    Setting Up the Modem The unit has an integral modem for remote management. It is already set up for dial-in access to the unit, with Port Use set to Terminal. If using the modem for dialed IP network connectivity (SNMP, Telnet, FTP, or trap dial-out): 1.
  • Page 14: Setting Up The Isdn Dbm

    Setting Up the ISDN DBM FrameSaver SLV 9128s and 9128-IIs may be equipped with an ISDN PRI or BRI DBM. These instructions are for units with ISDN backup capability. The following guidelines apply: Central site configuration guidelines: – Set up the ISDN DBM physical interface. –...
  • Page 15 Setting Up Automatic Backup Configuration The Automatic Backup Configuration feature, included on the Auto-Configuration menu, is used to automatically create alternate DLCI records and PVC connections on the ISDN DBM (backup) interface. This feature is already set up in FrameSaver units with a DBM. Single_Site_Backup is the default for a BRI DBM.
  • Page 16: Configuring Snmp Trap Managers And Trap Dial-Out

    Setting the Criteria for Automatic Backup 1. Enable Auto Backup. Main Menu Configuration Auto Backup Criteria When a failure occurs, the unit automatically enables the Alternate Link and traffic is rerouted over the backup (alternate) interface. 2. Specify When Auto Backup Allowed – Always or Restrict. If Restrict is selected, specify the days and hours of the week during which automatic backup can take place.
  • Page 17: Connecting To The Network

    If not, make sure both ends of the network cable are properly seated. The FrameSaver SLV 9128-II has a FR (Frame Relay) LED. It will be green when the unit is operating in Frame Relay mode and LMI is up, yellow when the unit is operating in Frame Relay mode and LMI is down, and it will be off when the unit is operating in Leased Line mode.
  • Page 18: Verifying The End-To-End Path

    Verifying the End-to-End Path After installation of a remote site unit, run an IP Ping test to ping the NMS at the central site and verify that the entire path from the remote unit to the NMS is functioning. To run the IP Ping test, NMS trap managers must have been configured for the remote unit.
  • Page 19 Connecting to the DSX 1. Connect the DB15 end of the DSX cable to the DSX-1 interface. 2. Connect the other end of the cable to the CPE (customer premises equipment, like a PBX). 3. Tighten the screws on each side of the connector to secure the cable. MODEM ENET POWER...
  • Page 20 – The FrameSaver SLV 9128 has a Port OK LED for each port. – The FrameSaver SLV 9128-II has one Port OK LED for both ports. If either port is enabled and active, the LED is on. If both ports are enabled and one of the ports is inactive, the LED is off.
  • Page 21: Connecting The Modem

    Connecting the Modem 1. Insert the RJ11C connector on the modem cable into the Modem/MDM interface. 2. Insert the other end of the cable into the phone service RJ11C jack. MODEM ENET POWER RJ11C Jack 00-16846 3. Verify modem operation. If Port Use is set to Terminal (dial-in access): –...
  • Page 22 Connecting to the ISDN This procedure only applies to a FrameSaver unit equipped with an ISDN DBM. 1. Insert the 8-pin connector on the ISDN cable into the DBM interface. 2. Insert the other end of the cable into the ISDN service jack. –...
  • Page 23: Connecting To The Ethernet

    Connecting to the Ethernet This procedure only applies to a FrameSaver SLV 9128-II. 1. Insert one 8-pin connector of the Ethernet cable into the Ethernet port. 2. Insert the other end of the cable into the Ethernet interface of the LAN where the NMS resides.
  • Page 24: Checking Pvc Connections

    Checking PVC Connections Check PVC connections to verify that all PVCs, including management PVCs, are configured, and to see whether the PVC is active or not. 1. Press Esc to return to the Status menu. 2. Select PVC Connection Status. The PVC Connection Status screen shows all PVC connections;...
  • Page 25: Connecting The Com Port To The Router

    Connecting the COM Port to the Router If the Modem PassThru feature will be used, the terminal or PC must be disconnected and the COM port connected to the router’s AUX port. A standard cable can be used. See Connectors, Cables, and Pin Assignments in the User’s Guide for additional information.
  • Page 26 The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne. CANADA – EMI NOTICE: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
  • Page 27: Government Requirements

    Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be included in the user documentation. Specific instructions are listed in the following sections. United States Notice to Users of the Telephone Network This equipment complies with Part 68 of the FCC rules. On the bottom of the housing is a label that contains, among other information, the FCC registration number for this equipment.
  • Page 28 When the unit has an ISDN PRI DBM, make the ISDN PRI connection using a USOC-type RJ48C jack. When ordering an ISDN line from the telephone company, specify the following: Service Order Code 6.0F Facility Interface Code 04DU-1SN Up to 23B Service for an ISDN PRI DBM – Supports up to 23 circuit-switched B-channels, with one local phone number for the entire T1 network connection.
  • Page 29 Canada Notice to Users of the Canadian Telephone Network The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
  • Page 30: Warranty, Sales, Service, And Training Information

    Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.

This manual is also suitable for:

Framesaver slv 9128-ii

Table of Contents