Send Pattern; Monitor Pattern - Paradyne iMarc SLV Operation Manual

Imarc slv
Table of Contents

Advertisement

Send Pattern

This test sends packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another iMarc device.
To send a pattern test on a link:
If the CIR is zero, the pattern will be sent at a rate of 1000 bps.

Monitor Pattern

This test monitors packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another iMarc device.
To monitor a pattern test on a link:
The current number of sequence and data errors are shown under the Result
column when the iMarc unit is in sync. An Out of Sync message appears when
5 frames out of 25 are missing or out of sequence.
These error counts are updated every second. If the maximum count is reached,
99999+ appears in these fields.
9000-A2-GB33-20
Main Menu→Test→[Network PVC Tests/Data Port PVC Tests/
T3 User Port PVC Tests/ISDN Call/PVC Tests]
If the selected DLCI is
configured as . . .
Standard or IP Enabled
Multiplexed
Main Menu→Test→[Network PVC Tests/Data Port PVC Tests/
T3 User Port PVC Tests/ISDN Call/PVC Tests]
May 2003
Then . . .
(Disruptive) appears
after Test
(Non-Disruptive)
appears after Test
5. Troubleshooting
And the default
Rate (Kbps) setting is . . .
100% of CIR
10% of CIR
5-25