Paradyne FrameSaver SLV 9820-C Installation Instructions Manual

Standalone unit

Advertisement

Quick Links

FrameSaver SLV 9820 Standalone Unit
Installation Instructions
Document Number 9820-A2-GN10-20
August 1999
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select Library
Technical Manuals
Select the following document:
9820-A2-GB20
FrameSaver SLV 9820 User's Guide
To request a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
FrameSaver SLV 9820 Models
There are two models of the FrameSaver 9820 product:
Model 9820-C – Central site model. Supports up to 120 PVCs.
Model 9820 – Remote site model. Supports up to 16 PVCs.

Package Checklist

Verify that your package contains the following:
FrameSaver SLV 9820 or 9820-C unit
Universal power supply with an attached cable and ferrite choke
Power cord appropriate for the wall-plug standard in your country (depends on
model ordered).
FrameSaver Frame Relay Devices.
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne FrameSaver SLV 9820-C

  • Page 1: Package Checklist

    We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain competitive prices for our products. Complete documentation for this product is available at www.paradyne.com. Select Library Technical Manuals FrameSaver Frame Relay Devices.
  • Page 2: Before You Begin

    Additional cables may be ordered. See Cables You Can Order on page 3 when ordering cables. Be sure to register your warranty at www.paradyne.com/warranty. Before You Begin If you ordered a wall mounting kit (Feature No. 9001-F1-891) for your FrameSaver unit, install the wall mounting before you start installing the unit.
  • Page 3: Safety Instructions

    Cables You Can Order Feature Part If connecting to . . . Order a . . . Number Number LAN adapter Adapter DB25 3100-F1-920 002-0069-0031 plug-to-8-position modular receptacle COM Port-to-LAN 3100-F2-910 035-0315-1431 adapter cable (14 feet – 4.3 meters) Equipment with X.21 cable kit, which 9008-F1-521 X.21 interfaces,...
  • Page 4: Installing The Power Supply And Cord

    Installing the Power Supply and Cord 1. Insert the power supply’s 4-prong plug into the POWER jack. When inserting the plug at the rear of the FrameSaver unit, align the plug with the notch above the POWER jack. Make sure the locking tab snaps securely into the jack.
  • Page 5 Connecting the COM Port to an Async Terminal or PC The FrameSaver unit must first be directly connected to a PC or asynchronous terminal (providing VT100 terminal emulation) to set up access and management of the unit. 1. Configure the VT100-compatible terminal or PC to be compatible with the access unit: –...
  • Page 6: A Quick Guide To Configuration

    A Quick Guide to Configuration The FrameSaver unit should operate using the default (factory-set) configuration options, with exception to the changes specified in these installation instructions. Refer to the following table for help in navigating through the menus. Press the . . . To .
  • Page 7 Network Operations Center (NOC) router (for management by the Network Service Provider). Multiple management PVCs then connect the central site unit to the remote site units using Paradyne’s proprietary PVC multiplexing method (embedded DLCIs).
  • Page 8: Verifying That Self-Test Passed

    Verifying that Self-Test Passed 1. Follow this menu selection sequence from the Main Menu and press Enter after each selection: Main Menu Status System and Test Status 2. Check the Self-Test Results column (in the center of the System and Test Status screen).
  • Page 9: Configuring Physical Interfaces

    Configuring Physical Interfaces The network and data port interfaces support three different port types: EIA-530, V.35 and X.21. If your application does not use V.35 interfaces, then the port type needs to be changed. If the Hardware Bypass feature will be used, both the network and user port interfaces should use the same type of interface.
  • Page 10: Automatic Configuration

    Setting Up Local Management at the Central Site 1. Create a DLCI for the data port. Configuration Data Ports DLCI Records 2. Save the configuration. 3. Create a Management PVC using the data port DLCI just created. Configuration Management and Communication Management PVC Minimally, enter the following options: –...
  • Page 11: Connecting To The Network

    Connecting to the Network Now that the FrameSaver unit is set up, the unit can be connected to the network. 1. Insert the DB25 connector of the network cable into the network data port. 2. Insert the other end of the cable into the NTU (EIA-530, V.35 or X.21). 98-16199 NOTE: After connecting the network cable, wait about a minute to allow...
  • Page 12: Setting Up Service Provider Connectivity At The Central Site

    Setting Up Service Provider Connectivity at the Central Site When management needs to be set up between a service provider’s customer and its network operations center (NOC), a non-multiplexed DLCI must be configured to carry management data between the customer’s central site and the NOC console. This requires that a frame relay discovered DLCI needs to be modified.
  • Page 13: Configuring Snmp Trap Managers And Traps

    Configuring SNMP Trap Managers and Traps Once the FrameSaver unit is connected to the network, SNMP trap managers and SNMP traps can be configured. To enter SNMP managers and configure traps: 1. Select SNMP Traps. Main Menu Configuration Management and Communication SNMP Traps 2.
  • Page 14 Connecting to the DTE (Router or FRAD) 1. Connect the appropriate cable to the Port connector. – If the DTE interface type is EIA-530A, the DTE can be directly connected to the Port connector. – If the DTE interface type is V.35 or X.21, a V.35 or X.21 adapter cable is required.
  • Page 15 Check that Data is Being Received 1. Return to the Main Menu. 2. Select Performance Statistics, and select an interface’s frame relay statistics (e.g., Network Frame Relay). Main Menu Status Performance Statistics Network Frame Relay 3. Verify that the Frames Received and Characters Received counts under the Frame Relay Link statistics are incrementing, and there are no errors under the Frame Relay LMI statistics.
  • Page 16 FrameSaver 9820 Rear Panel 98-16189 FrameSaver 9820 Front Panel 9820 FrameSaver FrameSaver NETWORK PORT 98-16201...
  • Page 17: Important Safety Instructions

    Low Voltage (SELV) output less than 240 VA available, certified for use in the country of installation. Paradyne power supply part number 327-0107-0031 is recommended. This power supply includes a special mating connector for connection to this equipment. 5. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
  • Page 18: Emi Warnings

    The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne. WARNING: To Users of Digital Apparatus in Canada: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
  • Page 19 CE Marking When the product is marked with the CE mark, this demonstrates full compliance with the following European Directives: Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within certain voltage limits, as amended by Directive 93/68/EEC.
  • Page 20: Warranty, Sales, Service, And Training Information

    Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.

This manual is also suitable for:

Framesaver slv 9820

Table of Contents