Table 3-24. T3 Network Line Performance Statistics (2 of 2)
9000-A2-GB33-20
Field or Statistic
What It Indicates
Status
The contents of the Status Events Register, which maintains a
history of events which have occurred at least once during an
interval. One or more of:
Y – A Yellow Alarm signal was detected during the interval.
S – A Loss Of Signal occurred during the interval.
O – An Out Of Frame defect occurred during the interval.
F – A Loss Of Frame occurred during the interval.
A – An Alarm Indication Signal was received during the interval.
none – No error event was stored in the Status Events Register.
Tot (valid nn)
The number of valid intervals in the previous 24 hours. If a
power cycle has occurred within that time, 96 intervals are not
available.
Worst Interval
The interval number during which the largest number of each
kind of error was detected.
May 2003
3. Status and Statistics
3-87