eoj text binary <binary>
eoj text set <text>
exit
formfeed disable
formfeed enable
kill
line <line>
lpd <line>
no eoj text
no queue name
no soj text
ppp <line>
queue name <text>
show
show history
show statistics
soj disable
soj enable
soj text binary <binary>
soj text set <text>
terminal <line>
terminal network
test print <number of lines>
tunnel <line>
write
modbus (modbus) level commands
MatchPort® b/g Pro Embedded Device Server Command Reference
Sets the end-of-job text allowing for binary characters.
<binary> = string in binary format that will be sent to the
printer at the
end of each print job.
Within [] use binary decimal up to 255 or hex up to 0xFF.
Sets the end-of-job text.
<text> = ascii string that will be sent to the printer at the
end of each
print job.
Exits to the configuration level.
Disables the printer from advancing to the next page at
the end of each
print job.
Forces the printer to advance to the next page at the end
of each print job.
Ends the current print job on this lpd line.
Enters the line level.
<line> = number of the line (serial port) to be configured.
Enters the configure lpd level.
<line> = number of the line (lpd serial port) to be config-
ured.
Removes the end-of-job string.
Removes the queue name.
Removes the start-of-job string.
Enters the serial line PPP level.
Sets the name of the queue that this lpd line belongs to.
<text> = name for the queue.
Displays the current configuration.
Displays the last 20 commands entered during the current
CLI session.
Displays statistics and status information for this lpd line.
Disables sending the start-of-job string after each print
job.
Enables sending the start-of-job string after each print job.
Sets the start-of-job text allowing for binary characters.
<binary> = string in binary format that will be sent to the
printer at the
beginning of each print job.
Within [] use binary decimal up to 255 or hex up to 0xFF.
Sets the start-of-job text.
<text> = ascii string that will be sent to the printer at the
beginning of
each print job.
Enters the configure-terminal level.
<line> = number of the terminal line (serial port) to be con-
figured.
Enters the configure-terminal level for the network.
Prints lines of text directly to the lpd line.
<number of lines> = number of lines to print.
Enters the tunnel level.
<line> = number of the tunnel line (serial port) to be con-
figured.
Stores the current configuration in permanent memory.