flush serial disable
flush serial enable
flush start character disable
flush start character enable
host <instance>
host mode sequential
host mode simultaneous
kill connection
local port <number>
no email connect
no email disconnect
promote host <number>
reconnect time <milliseconds>
show
show history
show status
start character <control>
write
connect (tunnel-connect:1) level commands
block network disable
block network enable
block serial disable
block serial enable
clrscrn
connect mode always
MatchPort® b/g Pro Embedded Device Server Command Reference
Characters already in the serial data buffer are retained
upon establishing
a connect mode tunneling connection.
Flushes the serial data buffer upon establishing a connect
mode tunneling
connection.
Enables forwarding of the connect start character into the
network.
Disables forwarding of the connect start character into the
network.
Enters the next lower level.
Specify the instance for the next lower level.
Connects to the first host in the list that accepts the con-
nection.
Selects simultaneous connections to all hosts on the host
list.
Disconnects the active connect mode tunneling connec-
tion or connections.
Sets a specific port for use as the local port.
<number> = the number of the port to use.
Discontinues sending email alerts upon establishing a
connect mode tunnel.
Discontinues sending email alerts upon closing a connect
mode tunnel.
Promotes the identified host, exchanging it place with the
host above it,
to adjust the order of the defined hosts.
Sets the reconnect time value for tunneling connections
established by the
device in milliseconds.
<milliseconds> = timeout in milliseconds.
Displays the current configuration.
Displays the last 20 commands entered during the current
CLI session.
Displays tunnel connect status.
Sets the connect mode start character.
The character may be input as text, control, decimal, or
hex.
A control character has the form <control>C.
A decimal value character has the form \99.
A hex value character has the form 0xFF.
Stores the current configuration in permanent memory.
Forwards (tunnels) network data in connect mode tunnel-
ing.
Discards all data coming in from the connect mode tunnel
before forwarding
it to the serial interface (generally used for debugging).
Forwards (tunnels) serial data in connect mode tunneling.
Discards all data coming in from the serial interface before
forwarding
it to the connect mode tunnel (generally used for debug-
ging).
Clears the screen.
Enables the tunneling server to always establish tunneling
5: Commands and Levels