protocol tcp aes
protocol telnet
protocol udp
protocol udp aes
show
show history
show statistics
ssh username <text>
tcp keep alive <milliseconds>
validate certificate disable
validate certificate enable
vip disable
vip enable
vip name <text>
write
host 7 (tunnel-connect-host:1:7) level commands
address <text>
aes decrypt key <hexadecimal>
aes decrypt key text <text>
aes encrypt key <hexadecimal>
aes encrypt key text <text>
MatchPort® b/g Pro Embedded Device Server Command Reference
Uses TCP protocol with AES encryption for connect mode
tunneling.
Uses Telnet protocol (with IAC) for connect mode tunnel-
ing.
Uses UDP protocol for connect mode tunneling.
Uses UDP protocol with AES encryption for connect mode
tunneling.
Shows the current configuration.
Displays the last 20 commands entered during the current
CLI session.
show connection statistics
Sets the SSH user name for use when establishing tun-
neling connections
with other devices.
<text> = SSH user name.
Enables TCP keep alive for connect mode tunneling and
sets the timer.
<milliseconds> = timer value, in milliseconds.
Skips verification of the server certificate when connect-
ing.
Requires verification of the server certificate when con-
necting.
Makes connections using the specified Address.
Makes connections using the VIP name.
Sets the VIP name.
Stores the current configuration in permanent memory.
Sets the remote host to establish tunneling connections
with.
<text> = IP address or host name of the remote host.
Sets the connect tunnel AES decrypt key with up to 16
bytes.
Each byte is represented by two adjacent hex digits.
Bytes may run together or be separated by optional punc-
tuation:
123ABC "12 3A BC" 12,3A,BC 12.3a.bc 12:3a:bc
Note that quotes must enclose the value if it contains
spaces.
Sets the connect tunnel AES decrypt key with up to 16
bytes.
Each byte is represented by a single character.
Note that quotes must enclose the value if it contains
spaces.
Sets the connect tunnel AES encrypt key with up to 16
bytes.
Each byte is represented by two adjacent hex digits.
Bytes may run together or be separated by optional punc-
tuation:
123ABC "12 3A BC" 12,3A,BC 12.3a.bc 12:3a:bc
Note that quotes must enclose the value if it contains
spaces.
Sets the connect tunnel AES encrypt key with up to 16
bytes.
Each byte is represented by a single character.
Note that quotes must enclose the value if it contains
spaces.
5: Commands and Levels
118
Need help?
Do you have a question about the MatchPort b/g Pro and is the answer not in the manual?