Offline Mode; Table 5-4 Additional Normal Operation Screens For Each Gt Inverter Unit In A Multiple Unit System; Table 5-5 Offline Mode Default Display - Xantrex GT2.5-NA Owner's Manual

Grid tie solar inverter
Table of Contents

Advertisement

Additional screens
for multiple units

Offline Mode

Offline default
display
Offline messages
for all systems
975-0245-01-01
http://www.wholesalesolar.com/inverters.html
* In a multiple unit system with network cables properly installed, the system
values displayed are for the entire system. For example, in a two-inverter
system, if inverter #1 is producing 1500 W and inverter #2 is producing
2000 W, both inverters display a total system power of 3500 W. Time online
and array readings are for the local inverter and PV array associated with that
inverter.
In addition, to the normal system message screens, additional screens specific to
each GT Inverter unit can be displayed when the unit is networked to other GT
Inverters. These screens are only available on multiple unit systems.
To view unit-specific screens in a multiple unit system:
1. Tap the Xantrex logo near the LCD to advance the display to the next screen.
Continue tapping until the final system message screen ("Grid Readings", in
Table 5-3 above) is displayed.
2. Tap again. Normal operation screens shown in Table 5-4 are displayed in the
order given, as you tap successively on the unit.
If you continue to tap the unit, then the LCD will cycle through all of the available
normal operation screens. Each message is displayed for up to 30 seconds. If you
do not tap again within that time period, then the LCD backlight turns off and the
display reverts to the default normal operation screen (Table 5-2).
Table 5-4 Additional Normal Operation Screens for Each GT Inverter Unit in a
Multiple Unit System
Tap
Display
Unit 1500W
6th time
Today 1.250kWh
Unit Lifetime
7th time
150kWh
At night and when no power is being produced by the PV array (offline mode), the
GT Inverter displays the screen shown in Table 5-5.

Table 5-5 Offline Mode Default Display

Display
Inverter
Offline
Additional message screens can be viewed when the system is offline by tapping
the Xantrex logo near the LCD. Each additional tap displays the next screen, in
the order shown in Table 5-6.
http://www.wholesalesolar.com/inverters.html
Front Panel Display Screens and What They Mean
Power being produced by this unit now.
Cumulative energy produced by this unit today.
Lifetime energy produced by this GT Inverter unit
Description
Displayed at all times while the system is offline.
Description
5–5