Preparing For The Installation; Figure 2-5 Conduit Hole And Knockout Locations - Xantrex GT2.5-NA Owner's Manual

Grid tie solar inverter
Table of Contents

Advertisement

Installation
Conduit
holes/knockouts

Preparing for the Installation

2–12
http://www.wholesalesolar.com/inverters.html
WARNING: Shock hazard
Check for existing electrical or plumbing prior to drilling holes in the walls.
Pre-plan the wire and conduit runs. Dual knockouts for 35 mm (1 3/8 inch) or
27 mm (1 inch) conduit holes are located on the bottom and back of the wiring
box—four dual knockouts in total. Two threaded 27 mm (1 inch) conduit holes are
located on each side of the wiring box (Figure 2-5).
For maximum safety, run AC, DC, and communication wires in separate conduits.
35 mm (1 3/8") and 27 mm (1")
dual knockouts
Bottom

Figure 2-5 Conduit Hole and Knockout Locations

Ensure your local utility is consulted for any requirements for connecting to or
returning power to the grid. Obtain all permits necessary to complete the
installation. Consult your local and national electrical codes for more information.
This section includes the following topics:
"Wiring" on page 2–13
"Circuit Breakers and Disconnect Switch" on page 2–13
"Other Materials Needed" on page 2–14
"Equipment Needed" on page 2–14.
Important:
In this manual "wiring" and "wires" are used in reference to both AC and
DC wiring/cabling and wires/cables.
http://www.wholesalesolar.com/inverters.html
27 mm (1") threaded
conduit holes
DC/AC
Disconnect Switch
Side
975-0245-01-01