Operating During Transition Between Grid Mode And Battery Mode; Transitioning From Grid Mode To Battery Mode; Transitioning From Battery Mode To Grid Mode - Xantrex Freedom X 1200 Owner's Manual

120v sine wave inverter
Table of Contents

Advertisement

Operating During Transition
Between Grid Mode and Battery
Mode
The Freedom X 1200's advanced power management is capable
of transitioning power from an AC source to DC source within a
fraction of a second and vice-versa.
The Freedom X 1200 automatically detects when shore power is
present and when it becomes unavailable or drops to less than
106 volts AC.
The transfer time can be set to two settings. For details see
Adjusting Feature Settings in Configuration Mode on page 1.
NOTICE
EQUIPMENT DAMAGE
When the transfer mode is set to UPS, connect only
l
sensitive digital equipment that requires fast AC transfer
times.
Appliances with motors, compressors, and heating
l
elements do not require a transfer mode of UPS. Set APL for
these devices to avoid damaging the transfer relay.
Failure to follow these instructions can result in equipment
damage.
975-0767-01-01

Operating During Transition Between Grid Mode and Battery Mode

Transitioning from Grid Mode to
Battery Mode
When the unit is operating in grid mode and shore power is lost,
the Freedom X 1200 has less than 20 milliseconds (default) to
switch to operating in battery mode (if the Power button is pressed
in the On position) and starts drawing power from the battery.
The operating mode indicator will change to Battery Mode and the
green Status LED for Battery Mode will light up.
However, if the Power button is in Standby, this transition does
not happen and the display panel turns off.
Transitioning from Battery Mode to
Grid Mode
When the unit is operating in Battery Mode and shore power
becomes available, the Freedom X 1200 begins a 20-second
countdown to verify the stability of the shore power. If shore
power remains stable for a 20-second countdown, at the end of
the countdown, the Freedom X 1200 will switch to shore power
mode within 20 milliseconds and start drawing power from the AC
source.
The operating mode indicator will change to grid mode and the
green Status LED for grid mode will light up.