Setup Mode - Xantrex Freedom 458 Owner's Manual

Inverter/charger basic remote
Hide thumbs Also See for Freedom 458:
Table of Contents

Advertisement

Setup Mode

Enter the SETUP mode by pressing and holding SETUP for five
seconds until the LED blinks. The Freedom Remote is connected to a
458 Series if at least one DC VOLTS LED is On. After five seconds of
no activity, the Freedom Remote automatically exits from the SETUP
mode. Use the Freedom Remote buttons SET AHRS
SET TYPE to select SETUP features. Refer to the following template.
OPERATING TIP: Battery type and Battery Capacity are the most
critical setup settings.
CHARGE:
Sets amp hours
(458 Series units only)
SET AHRS
Using CHARGE, set the amp-hour rating of the battery bank. This
information is used to determine the charge parameters for the battery.
Default setting varies. 1000 W: 200 amp hours
SET IDLE
Using INVERT, select Idle setting. If present inverter loads are less than
the selected value, the inverter will remain in Idle Mode. Idle mode
prevents unnecessary power drain on the battery when no AC loads are
in use. When an AC load is turned On and the load draw exceeds the
idle value, the unit begins full power inverting. When the appliance is
turned Off, the inverter returns automatically to Idle mode. A setting of
"0" disables Idle Mode.
Default: Freedom: 4 watts, 458 Series: 5 watts.
Battery Capacity (Amp-hours)
Applies only to 458 Series
(458 Series Only) 1500–2000 W: 400 amp hours
Idle Load (Watts)
Changing this setting is not normally recommended.
INVERT:
POWER SHARE:
Sets Idle Mode
2500–3000 W: 600 amp hours
SET IDLE or
Sets Battery Type
5

Advertisement

Table of Contents
loading