Inverter Location - Xantrex GT2.5-NA Owner's Manual

Grid tie solar inverter
Table of Contents

Advertisement

Installation

Inverter Location

2–4
http://www.wholesalesolar.com/inverters.html
WARNING: Burn hazard
Do not install in a location where people can accidentally come into contact with the front
of the inverter. High temperatures can be present on the face of the inverter, causing a
potential burn hazard.
In extreme conditions, the GT Inverter chassis can reach temperatures over 70° C
(158° F), which can cause skin burns if accidentally touched. Ensure that the GT Inverter
is located away from normal traffic areas.
Inverter failure due to improper installation will void the inverter warranty.
Consider the following when determining where to install the inverter.
Fire Safety
Do not install anywhere near combustible or flammable materials.
The GT Inverter uses a Type 3R-rated enclosure (vertical mount
Indoor/Outdoor
only) that can be mounted indoors or outdoors. (Type 3R
enclosures are intended for outdoor use primarily to provide a
degree of protection against falling rain; and to be undamaged by
the formation of ice on the enclosure.)
While the 3R-rated enclosure protects the GT Inverter from
moisture, outdoor installations should be located away from lawn
sprinklers and other sources of spray.
Orientation
The GT Inverter must be mounted vertically on a wall or pole.
Do not mount the GT Inverter horizontally.
Ensure that the GT Inverter is mounted in a location where the
Temperature
ambient temperature range is
At extreme hot or cold temperatures, the front panel LCD may not
function normally.
At higher temperatures, the GT Inverter may derate power.
See"Output Power vs. Ambient Temperature at Various DC
Voltages" on page A–4 and "Environmental Specifications" on
page A–6.
Outdoors, the GT Inverter requires at least 100 cm (39 inches) of
Ground
clearance between the bottom of the unit and the ground.
Clearance
Indoors, it is recommended that the same clearance between the
bottom of the unit and the floor be used.
To minimize copper losses, ensure that wire lengths between the
Distance
PV array and the GT Inverter and between the inverter and the
Main Utility Service Panel are kept to a minimum.
Maximum distances will depend on wire gauges used and PV
array output voltages.
http://www.wholesalesolar.com/inverters.html
-25
to +65
C (-13
to +149
°
°
°
975-0245-01-01
F)
°
.