Electrical Specifications; Input; Output - Xantrex GT2.5-NA Owner's Manual

Grid tie solar inverter
Table of Contents

Advertisement

Specifications

Electrical Specifications

Input

Input voltage, Maximum Power Point range
Absolute maximum array open circuit voltage
Maximum input current
Maximum array short circuit current
Recommended PV array power
Reverse polarity protection
Ground fault protection

Output

Model numbers
Maximum output power
Nominal output voltage
Operating range, utility
voltage (default)*
Nominal output frequency
Operating range, utility
frequency (default)*
Maximum continuous
output current
Output overcurrent
protection
Maximum utility backfeed
current
Total Harmonic Distortion
Power factor
Utility monitoring—
islanding protection
Output characteristics
Output current waveform
*
Requires Utility permission and qualified service personnel to change settings.
A–2
http://www.wholesalesolar.com/inverters.html
GT2.5
14.1 A DC
Up to 2750 W
GT2.5-NA-DS-240
GT2.5-NA-DS-240-POS
GT3.0-NA-DS-240
2500 W AC
3000 W AC
240 V
240 V
211 to 264 Vac
211 to 264 Vac
11.8 A
14.2 A
15 A RMS
<3%
http://www.wholesalesolar.com/inverters.html
GT3.0
195 to 550 Vdc
600 Vdc
16.9 A DC
24 A DC
Up to 3300 W
Short circuit diode
GF detection, I
> 1 A
DIF
GT3.3-NA-DS-240
GT3.3-NA-DS-240-POS
3300 W AC
240 V
211 to 264 Vac
60 Hz
59.3 to 60.5 Hz
15.6 A
20 A RMS
0 A
<3%
<3%
>0.9
Vac, fac as per UL1741
Current source
Sine wave
GT3.3
18.5 A DC
Up to 3600 W
GT3.3-NA-DS-208
GT3.3-NA-DS-208-POS
3300 W AC
208 V
183 to 228 Vac
18 A
<3%
975-0245-01-01