Using The Modified Pmc Compatible Ejector Lever; Replacing The Cntl 4000 Module - Polycom DOC2709A Hardware Manual

Collaboration server
Table of Contents

Advertisement

Polycom RealPresence Collaboration Server (RMX) 4000 Hardware Guide

Using the Modified PMC Compatible Ejector Lever

On the RMX 4000 most components are fitted with identical ejector levers that are used to
release or fasten the component's to their slot.
This ejector lever can be moved to three positions:
Warning!
Once the removal sequence is initiated the process cannot be terminated and the HS led flashes
when activated.

Replacing the CNTL 4000 Module

The CPU module is the management system of the RMX 4000. Use the following procedure
to replace a CNTL 4000 Module:
1
2
3
2-2
Closed/Locked - Ejector lever(s) are gently pushed up against the card's panel and is
locked. Ensure that the lock catch is in the standard closed position (shifted to the right
as shown below).
Handle
Partially Open - For card powering down mode. Partially open the ejector lever(s) until
the blue HS LEDs on the card and the Control Unit start flashing. When the HS LED is
constantly lit the card is in a powered down mode and you can remove the card.
Fully Open - In this position the card is released from the MCU housing and can be
removed.
Lever Fully Open - Pull the lever handle(s) to a fully open position
(approx. 70 degrees), as shown here
Ensure that the power switch/circuit switch on the RMX 4000 is turned OFF (O).
Unscrew the captive screws on the front panel of the
m
odule to the chassis.
Use the metal ejector lever to pull the
Backplane.
Closing the Lever - Make sure that the lever is in an open
position and push card close to the chassis till the lever engages.
With your thumb holding the "handle" and your index finger
holding the catch fully to left, push the card against the chassis
whilst closing the lever. Use your thumb to push the card into
place, and then lock the catch into its place by using your thumb to
push it to the right. Make sure that the lever is locked.
Unlocking the Lock Catch - With your thumb holding the "handle"
and your index finger shifting the catch to left, gently pull the handle
away from the chassis until the lever is "fully open"
CNTL
4000 Module out of its slot in the
CNTL
4000 Module that secure the
Polycom, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Realpresence rmx 4000

Table of Contents