The Enable Menu; The Mode Menu; The Baud Rate Menu; The Parity Menu - Xante Accel a Writer 812 Manual

Hide thumbs Also See for Accel a Writer 812:
Table of Contents

Advertisement

The Enable Menu

The Enable menu, RS232:ENABLE, allows you to enable (YES) or
to disable (NO) the RS232 interface. The factory default is YES.

The Mode Menu

The Mode menu, RS232:MODE, allows you to select PostScript, an
emulation mode (HP-GL or PCL5), or automatic switching between
PostScript and PCL5 modes. The mode options are PS STD, PS BIN,
PS TBCP, HPGL, PCL5, AIS RAW, AIS BIN, and AIS TBCP. AIS
options switch between PostScript and PCL5. The factory default is
PS STD.
PS STD
PS BIN
PS TBCP
HPGL
PCL5
AIS RAW
AIS BIN
AIS TBCP
See the "PostScript and Emulations" section at the end of this
chapter for more details on selecting emulations.

The Baud Rate Menu

The Baud Rate menu, RS232:BAUD RATE, allows you to select a
baud rate of 9600, 19200, and 1200. The factory default rate is 9600.

The Parity Menu

The Parity menu, RS232:PARITY, allows you to select none, even,
odd, mark, or space parity. The factory default parity is NONE.

The Flow Control Menu

The Flow Control menu, RS232:FLWCNTL, allows you to select
XON/XOFF (software) or DTR (hardware) flow control. The factory
default is XON/XOFF.
5-18
Configurationbb
for standard PostScript
for binary PostScript
for tagged binary communication protocol
PostScript
for HP–GL 7475A emulation
for HP PCL 5 emulation
for automatic interface switching
for binary automatic interface switching
for tagged binary communication protocol
automatic interface switching
______________________________________

Advertisement

Table of Contents
loading

This manual is also suitable for:

Accel-a-writer 812

Table of Contents