Freeze; Iadj; Iadjrst - Barco PDS User Manual

Table of Contents

Advertisement

_K==oÉãçíÉ=`çåíêçä
Remote Commands
cobbwb
f^ag
f^agopq
f^o=
126
Parameters:
-i (input): 5-6 (PDS-701) 5-8 (PDS-901 and PDS-902)
-t (EDID type): 0 - analog, 1 - digital (Default: 1)
Query Format: EDIDTYPE -i(input) -?
Query Response: EDIDTYPE -i(input) -t (EDID type) --min 0 --max 1
List Format: EDIDTYPE -i(input)
List Response:
0:"Analog"
1:"Digital"
Description: Freezes the input on program.
Command Format: FREEZE -m (mode)
Parameters: -m (mode): 0-off, 1-on (Default: off)
Query Format: FREEZE -?
Query Response: FREEZE -m (mode) --min 0 --max 1
Description: Selects the input path to be adjusted (preview or program). This
command is valid only for the PDS-902.
Command Format: IADJ -p (path)
Parameters:-p (path): 0-preview, 1-program
Query Format: IADJ -?
Query Response: IADJ -p (path)
List Format: IADJ --list
List Response:
0: "Preview"
1: "Program"
Description: Reset the input timing parameters to default values for analog. This
command is only available for analog input types.
Command Format: IADJRST -i (input)
Parameters: -i (input): 1 - 6 (PDS-701); 1 - 8 (PDS-901/902)
Query Format: N/A
Query Response: N/A
Description: Adjust Input Aspect Ratio
(5 - 8 only if type is analog)