Add / Delete Proximity Tags - Visonic PowerMaster-10 G2 User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10 G2:
Table of Contents

Advertisement

MENUS AND FUNCTIONS
Return to step 3
1
For detailed instructions on how to select the setting options – refer to section B.1 and section B.2.
2
The display shows the 1
system) / 48 User Codes (in PowerMaster-30 G2). If you have not yet changed the default code 1111, we
recommend that you change it now.
3
a. The display shows the user code currently programmed in this location (e.g. 5327).
b. The cursor blinks on the first digit of the code.
c. If the location is free the display will be blank ( - - - - ).
4
You can move the cursor to the next or previous digit by pressing
erases the digit of the cursor + all digits right of the cursor.
5
a. The new code is momentarily displayed without the cursor before reverting to step 3.
b. If Partition is enabled, continue to step 6 (applicable to PowerMaster-30 G2 only).
6
You can now repeat steps 3 - 5 to program or edit another user code. To end this session and to select
other menu options or to quit programming – follow the instructions in section B.2.
7
This setting can be performed only after completing steps 1 - 5 of section B.4A.
8
The
symbol now appears next to the newly selected Partitions.
9
You can now repeat steps 3 - 7 to program or edit another user code.
B.5 Add / Delete Proximity Tags
A proximity tag may be assigned to each of the PowerMaster-10 G2 user codes 1-8 / PowerMaster-30 G2 user
codes 1-32 that can be used instead of the user codes to perform a variety of functions, for example, arming,
disarming, reading the event log, etc.
Whenever a user code is required you can simply present a valid proximity tag instead of entering the user
code. Each tag should be assigned with a serial No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2) that
corresponds to the User Code No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2) and enrolled into the
system correspondingly.
*
The partition
authorization of the tags is identical to their corresponding user codes. For example, proximity tag
3 is assigned to user code 3.
 Here you can add (enroll) new proximity tags or delete tags as required.
Carefully read the section titled "Additional Information" according to the indicated references
table at end of this section.
A. To Add (Enroll) a Proximity Tag
1.
PROXIMITY TAGS
2.
ADD NEW TAG
3.
ENROLL NOW or
ENTR ID:xxx-xxxx
4.
DEVICE ENROLLED
Go to step 5
5.
T01:Tag (Prox)
24
with Partition 1 and 3 only, press
A "Happy Tune" 
Additional Information (section B.4)
st
User Code (Master User) in the list of 8 User Codes (in PowerMaster-10 G2
Enter the [USER SETTINGS] menu, select the [PROXIMITY TAGS] option
and press
The display will read [ADD NEW TAG].
To begin the process of enrolling a new proximity tag press
Present the proximity tag to the control panel within the timeout period.
If enrollment was successfully completed, a "Happy Tune" ☺ sounds and
the display reads [DEVICE ENROLLED] for a short duration and then
changes to read the tag's details.
The display shows the allocated tag serial No (user No.), which is always the
first free number, for example: [T01:Tag (Prox)].
sounds. The display confirms the Partition setting.
1
.
3
4
D-303223 PowerMaster-10/30 G2 User's Guide
to confirm.
or
. Pressing
1
etc – see
9
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30 g2

Table of Contents