Z01 24.5C
Z01:Temp. Sensor
Guest room
DEVICE TESTS END
9.
or
D. To Test all other Devices
TEST ALL DEVICES
10.
11.
NOT ACTIVE NNN
Z01 NOT ACTIVE
Z01 CONTACT
FRONT DOOR
12.
13.
DEVICE TESTS END
READY 00:00
1
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
2
If you have not already changed your personal code number, use the default setting – 1111.
3
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will
also provide the link quality indication – see PowerMaster Installer's Guide.
4
To skip the SIRENS TEST and select the other devices TEST, press
5
If the panel's display reads "SIREN P", this indicates that the control panel's siren is currently being tested.
6
The Periodic test can be performed on a maximum of two wireless sirens (including one internal siren) and
the sirens of enrolled smoke sensors. Outdoor sirens are activated with low volume.
7
If no temperature sensor is enrolled in the system, the display reads
8
The displayed temperature can be in Celsius or Fahrenheit according to the programmed settings of the
Temperature Sensor.
9
To activate system devices during the "Periodic Test"; make sure the device LED lights when activated:
Contact sensor: Open or close the door or window protected by the contact.
Motion sensors: Perform a "walk test" of the detector as explained in the detector's datasheet.
Smoke sensors: Perform a "Diagnostic test" as explained in the detector's datasheet.
Keyfob:
Keypads:
Repeater:
Other devices:
10
a. Three seconds after the device is displayed, the device LED blinks to assist you to identify ("it's me").
b. To end the session, press the
D-303223 PowerMaster-10/30 G2 User's Guide
The control panel reads the temperature of each zone. The display alternates
between the temperature, the sensor number and the sensor location.
Repeatedly click the
(by Temperature Sensor).
When the temperature of all zones has been reviewed, the display reads
[DEVICE TESTS END]. Press the
test and then move to the next step to test the other devices.
The display now reads [TEST ALL DEVICES].
To enter the devices test procedure press
The display reads [NOT TESTED NNN]. NNN indicates the number of enrolled
devices in the panel that have not been tested yet. This number automatically
drops one count for every tested device. To initiate devices test, press
The display shows the 1
alternates between the device number, the device type (e.g. magnetic
contact, keyfob, keypad, etc.), and the device location.
The test is performed by activating each device as explained in point 9 in the
table below.
Click
When all devices have been activated, the display reads [DEVICE TESTS
END] followed by [READY 00:00].
Additional Information (Periodic Test)
Activate any of the keyfob buttons.
Perform a disarm or arm routine or press any other key that activates the LED.
Follow the "Diagnostic Tests" described in the repeater's datasheet.
In general, follow the "Diagnostic Tests" described in the device's datasheet or activate
any of its functions.
button until the display reads [
TESTING THE SYSTEM
button to review the temperature of each zone
st
device in the list of untested devices. The display
to scroll through the list of all untested devices.
or the
button to confirm the
.
.
"NO EXISTING DEV.
".
<OK> TO EXIT
] then press
8
.
10
.
45