USER SETTINGS

Enrolling Proximity Tags (optional)

When partition is enabled: Each proximity tag
assigned to a partition will function as determined in
"Setting the User Codes". Therefore, each proximity
tag must be assigned a relevant user code. For
example, proximity tag 3 is assigned to user code 3.
Up to 8 proximity tags can be enrolled to the
PowerMaxExpress control panel.
Proximity tag enrolling involves the following steps:
A. Having
entered
successfully (see Entering the User Settings
Menu), Click the
if necessary) until the display will read:
E N R O L L
B. Click
. The display will read:
T a g N o :
C. Click
to initiate a transmission from the chosen tag:
P R E S E N T T A G
D. Present the tag to the MKP-160 keyprox left side.
In response, the "Happy Tune" (- - - –––) will sound
and the display will change to:
T a g N o :
A dark box will appear at the far right, indicating that
the chosen tag has been enrolled.
E. Click
tag (2, 3,...8), as described in step D.
F. From this point on, you may continue in several
different directions:
 If you wish to enroll another tag, select the
desired number by:
- Clicking
- Clicking
- Clicking
 To return to the main menu, click
will bring back the display:
< O K > T O E X I T
You may now review and select any other mode on
the User menu (by clicking

Deleting Proximity Tags

Proximity tag memory locations must be cleared
(enrolled ID must be deleted) before enrolling a new
ID. To delete an existing ID, proceed as follows:
A. Select the desired memory location, as described
in the previous paragraph, steps A-C. If, for
example, you selected Tag No. 5, the display will
read:
24
your
Master
User
button (repeatedly,
P R O X T A G
1
. The display will prompt you
1
and enroll the next proximity
to go up (678.....)
to go down (4
3
2.....)
 <tag#>.
or
T a g N o .
B. Click
< O F F > T O D E L E T E
C. Click
T a g N o .
Note that the dark box at the far right has
disappeared. It is now possible to enroll a new ID. It
is also possible to leave the cleared zone or memory
Code
location free and simply exit to the main menu.

Automatic Arming Option

You can determine that the system will be automatically
armed at any desired time.
Having entered master user code successfully, click
until AUTO ARM OPTION is displayed.
From here, proceed as follows:
PRESS
I
OK
If not satisfied
press
I
OK
I
OK
You may now select any other item on USERS
SETTINGS menu or quit programming process by
clicking
displayed, click

Setting Arming Time

Having entered your Master User Code successfully
(see above - Entering the User Settings Menu), click
. This
button (repeatedly, if necessary) until the
display will read:
From here, proceed as follows:
).
PRESS
I
OK
digits] (e.g.
12:55 A)
I
OK
D-303974 PowerMaxExpress User's Guide
5
. The display will change to:
. The display will change to:
5
RESULTANT DISPLAY
enable autoarm
(if this is the current option)
disable autoarm
disable autoarm
AUTO ARM OPTION
. When "<OK> TO EXIT" is
I
OK
.
AUTO ARM TIME
RESULTANT DISPLAY
arm time_ _ : _ _ A
[time
arm time 12:55 A
arm time 12:55 A
AUTO ARM TIME

Advertisement