Built-in Alarm Sounder

The PowerMaster panel has a high power siren built-in that sounds in case of alarm to deter intruders and to
summon help.
The maximum operating time of the siren is configured by the installer according to local regulations.
Continuously ON when initiated by a burglar zone or a 24-hour zone, and when a user initiates a "panic alarm".
When initiated by a fire zone (smoke is detected) ON - ON - ON - pause - ON - ON - ON - pause - ........ and so on.
If there is nobody around to disarm the system upon alarm, the siren will sound for the time duration set by the
installer - then will stop. If enabled, the strobe light will keep flashing until the system is disarmed or the siren will
stop as configured by the installer.
Alarm Type
Graphic Representation of Signal
–––––––––––––––––––––––––––––––
Burglar / 24
hour/ Panic
– – –
Fire
Gas (CO)
– – – –
–– (both external and internal sirens)
Test*
*
Not included in all models

General Audible Indicators

The sounds you will hear while using the control panel are:
Sound
Definition
Single beep, heard whenever a key is pressed
Double beep, indicates automatic return to the normal operating mode (by timeout).
Three beeps, indicates a trouble event
Happy Tune (- - - –––), indicates successful completion of an operation.
♫
♫
Sad Tune (–––––), indicates a wrong move or rejection

Other Audible Indicators

Pre-recorded voice announcements respond to your commands by announcing what the system is doing and by
prompting you to perform certain actions. They also announce alarms, troubles and identify the source of each
event.

LCD Display

The display is a single line, backlit 16-character LCD used to display system status and events, time and date,
programming instructions and also an event log file which is accompanied by the date and time of each event.
The normal display alternates with the time and the system status, for example:
READY
HH:MM
(alternating)
READY
MEMORY
1
Refers to PowerMaster-30 G2 with voice option only
D-303223 PowerMaster-10/30 G2 User's Guide
– – –
– – –
– – – .................
– – – –
– – – –
– – – –
........
1
INTRODUCTION
Verbal Description of Signal
ON continuously
ON - ON - ON - pause - ON - ON - ON - pause.....
ON - ON - ON - ON - pause - ON - ON - ON - ON -
pause.....
ON for 2 seconds (once)