PowerMaster-10 G2
Time to Charge
80 % ( 13 Hrs)
Optional Backup
See "Backup Battery Options" above
Battery Pack
Time to Charge
80 % ( 24 Hrs)
(optional backup
battery pack)
Wired Detectors
NA
Total (Sum)
Current
Site External Siren
NA
Current (EXT)
Site Internal Siren
NA
Current (INT)
PGM
Current sink to control panel GND 100 mA
max.
Max. external DC voltage +30 VDC
High Current /
NA
Short Circuit
Protection

E4. Communication

PowerMaster-10 G2
Communication
PSTN; GSM; GPRS; IP (for future use)
Built-in Modem
300 baud, Bell 103 protocol
Data Transfer to
Via RS232 serial port
Local Computer
Report
2 Monitoring Stations, 4 private telephones
Destinations
Reporting Format
SIA, Contact ID, Scancom, SIA IP, Visonic
Options
PowerNet.
Note: For UL Listed product, the
communication formats used are SIA and
Contact ID.
Pulse Rate
10, 20, 33 and 40 pps - programmable
Message to Private
Tone
Phones
Ring Detection
The unit does not support ring detection without
DC voltage present on the telephone lines.

E5. Physical Properties

PowerMaster-10 G2
Operating Temp.
14°F to 120°F (-10°C to 49°C)
Range
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)
D-303223 PowerMaster-10/30 G2 User's Guide
APPENDICES
PowerMaster-30 G2
by GP or equivalent.
4. 9.6V 2200 mAh, rechargeable NiMH battery
pack (special order) or equivalent.
5. 7.2V 1800 mAh, rechargeable NiMH battery
pack, p/n GP180AAH6BMX, manufactured
by GP only.
Caution! Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Note: For compliance with UL standards the
battery backup period shall exceed 24 hours and
12 hours for compliance with CE standards.
80 % ( 30 Hrs) for all battery types
See "Backup Battery Options" table above
NA
36* mA max.
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
450* mA max @ 12.5 VDC when powered by
AC/DC (10.5 VDC when in standby mode)
*
Total PowerMaster-30 G2 output current
(of INT & EXT sirens, PGM output and
detectors) cannot exceed 550 mA.
Current sink to control panel GND 100 mA
max.
Max. external DC voltage +15 VDC
All outputs are protected (automatic reset fuse)
PowerMaster-30 G2
PSTN; GSM; GPRS; IP (for future use)
300 baud, Bell 103 protocol
Via RS232 serial port
2 Monitoring Stations, 4 private telephones
SIA, Contact ID, Scancom, SIA IP, Visonic
PowerNet.
Note: For UL Listed product, the
communication formats used are SIA and
Contact ID.
10, 20, 33 and 40 pps - programmable
Tone or voice
The unit does not support ring detection without
DC voltage present on the telephone lines
PowerMaster-30 G2
14°F to 120°F (-10°C to 49°C)
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)