B.5 Programming the Duress Code
A duress (ambush) alarm message can be sent to the Monitoring Station if you are forced to disarm the system under
violence or menace. To initiate a duress message, you must disarm the system using a duress code (2580 by default).
A. To Program the Duress Code
1.
DURESS CODE
2.
DURESS CODE 2580
3.
DURESS CODE 6973
Return to step 1
1
For detailed instructions on how to select the setting options – refer to sections A.1 and A.2.
2
The display shows the default duress code (2580).
3
Do not set the duress code the same as an installer or user code.
4
To end this session and to select other menu options or to quit programming – follow the instructions in
section A.2.
B.6 Add / Delete Proximity Tags
A proximity tag may be assigned to each of the PowerMaster-10 G2 user codes 1-8 / PowerMaster-30 G2 user
codes 1-32 that can be used instead of the user codes to perform a variety of functions, for example, arming,
disarming, reading the event log, etc.
Whenever a user code is required you can simply present a valid proximity tag instead of entering the user
code. Each tag should be assigned with a serial No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2) that
corresponds to the User Code No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2) and enrolled into the
system correspondingly.
*
The partition
authorization of the tags is identical to their corresponding user codes. For example, proximity tag
3 is assigned to user code 3.
♦ Here you can add (enroll) new proximity tags or delete tags as required.
Carefully read the section titled "Additional Information" according to the indicated references
table at end of this section.
A. To Add (Enroll) a Proximity Tag
1.
PROXIMITY TAGS
2.
ADD NEW TAG
3.
ENROLL NOW or
ENTR ID:xxx-xxxx
4.
DEVICE ENROLLED
*
Duress Code is not applicable for UL installations
D-304829 PowerMaster-10/30 G2 User's Guide
*
Enter the [USER SETTINGS] menu, select the [DURESS CODE] option and
1
press
.
At the blinking cursor position, key in the Duress Code you wish to program,
2, 3
for example, 6973.
When the duress code you wish to program appears on the display, press
.
A "Happy Tune"
sounds. The display confirms the saved code.
Additional Information (section B.5)
Enter the [USER SETTINGS] menu, select the [PROXIMITY TAGS] option
1
and press
.
The display will read [ADD NEW TAG].
To begin the process of enrolling a new proximity tag press
Present the proximity tag to the control panel within the timeout period.
If enrollment was successfully completed, a "Happy Tune"
MENUS AND FUNCTIONS
3
4
1
etc – see
.
☺ sounds and
27