1. FUNCTIONS AND CONFIGURATION

1.8 Configuration including auxiliary equipment

(1) MR-J3-100B or less
(a) For 3-phase or 1-phase 200V to 230VAC
R S T
(Note 3)
Power supply
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
(Note 2)
Line noise
filter
(FR-BSF01)
L
1
L
2
L
3
(Note 2)
Power factor
improving DC
reactor
(FR-BEL)
Regenerative option
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
3. A 1-phase 200V to 230VAC power supply may be used with the servo amplifier of MR-J3-70B or less.
For 1-phase 200V to 230VAC, connect the power supply to L
specification.
POINT
Equipment other than the servo amplifier and servo motor are optional or
recommended products.
Servo amplifier
U V
P
1
P
2
P
C
L
11
L
21
CN5
CN3
CN1A
CN1B
W
CN2
CN4
(Note 1)
Battery
MR-J3BAT
L
and leave L
1
2
3
1 - 21
Personal
computer
MR Configurator
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
Servo motor
open. Refer to section 1.3 for the power supply
Junction terminal
block
-P
.
1
2