5. PARAMETERS
No.
Symbol
PB42
For manufacturer setting
PB43
PB44
PB45

5.2.2 Detail list

No.
Symbol
PB01
FILT
Adaptive tuning mode (adaptive filter )
Select the setting method for filter tuning. Setting this parameter to "
tuning mode 1) automatically changes the machine resonance suppression filter 1
(parameter No. PB13) and notch shape selection (parameter No. PB14).
Setting
0
1
2
Note. Parameter No. PB13 and PB14 are fixed to the initial values.
When this parameter is set to "
done the predetermined number or times for the predetermined period of time, and the
setting changes to "
changes to "
to the machine resonance suppression filter 1 and notch shape selection. However, this
does not occur when the servo off.
Name and Function
Notch frequency
0 0 0
Filter adjustment mode
Automatically set parameter
Filter OFF
(Note)
Parameter No. PB13
Filter tuning mode
Parameter No. PB14
Manual mode
1", the tuning is completed after positioning is
2". When the filter tuning is not necessary, the setting
0". When this parameter is set to "
Name
Machine resonance point
Frequency
Frequency
Filter tuning mode selection
0", the initial values are set
5 - 10
Initial Value
1125
0004h
0.0
0000h
Initial
Unit
Value
0000h
1" (filter
Unit
Setting
Range