Mitsubishi Electric Melservo-J3 Series MR-J3-B Instruction Manual page 229

Melservo j3 series general-purpose ac servo sscnet compatible
Hide thumbs Also See for Melservo-J3 Series MR-J3-B:
Table of Contents

Advertisement

11. OPTIONS AND AUXILIARY EQUIPMENT
(b) MR-J3-350B4 MR-J3-500B(4) MR-J3-700B(4)
Always remove the wiring (across P-C) of the servo amplifier built-in regenerative resistor and fit the
regenerative option across P-C.
The G3 and G4 terminals act as a thermal sensor. G3-G4 is opened when the regenerative option
overheats abnormally.
When using the regenerative resistor option, remove the servo amplifier's built-in regenerative resistor
terminals (across P-C), fit them back to back, and secure them to the frame with the accessory screw as
shown below.
Mounting method
Accessory screw
Always remove wiring (across P-C) of servo
amplifier built-in regenerative resistor.
Servo amplifier
P
C
(Note 2)
5m or less
Note 1. When using the MR-RB51 MR-RB3G-4 MR-RB5G-4 MR-RB34-4 MR-RB54-4, forcibly
cool it with a cooling fan (92 92, minimum air flow : 1.0m
2. Make up a sequence which will switch off the magnetic contactor (MC) when abnormal heating
occurs.
G3-G4 contact specifications
Maximum voltage: 120V AC/DC
Maximum current: 0.5A/4.8VDC
Maximum capacity: 2.4VA
Regenerative option
P
C
G3
G4
Cooling fan(Note 1)
11 - 26
3
).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents