11. OPTIONS AND AUXILIARY EQUIPMENT
(d) MR-J3-11KB(4)-PX to MR-J3-22KB(4)-PX (when using the regenerative option)
The MR-J3-11KB(4)-PX to MR-J3-22KB(4)-PX servo amplifiers are not supplied with regenerative
resistors. When using any of these servo amplifiers, always use the MR-RB5E, 9P, 9F, 6B-4, 60-4 and
6K-4 regenerative option.
The MR-RB5E, 9P, 9F, 6B-4, 60-4 and 6K-4 are regenerative options that have encased the GRZG400-
1.5 , GRZG400-0.9 , GRZG400-0.6 , GRZG400-5.0 , GRZG400-2.5 , GRZG400-2.0 respectively.
When using any of these regenerative options, make the same parameter setting as when using the
GRZG400-1.5 , GRZG400-0.9 , GRZG400-0.6 , GRZG400-5.0 , GRZG400-2.5 , GRZG400-2.0
(supplied regenerative resistors or regenerative option is used with 11kW or more servo amplifier).
Cooling the regenerative option with cooling fans improves regenerative capability.
The G3 and G4 terminals are for the thermal protector. G3-G4 is opened when the regenerative option
overheats abnormally.
Servo amplifier
P
1
P
C
Configure up a circuit which
shuts off main circuit power
when thermal protector operates.
Note. Specifications of contact across G3-G4
Maximum voltage : 120V AC/DC
Maximum current : 0.5A/4.8VDC
Maximum capacity : 2.4VA
Servo amplifier
MR-J3-11KB-PX
MR-J3-15KB-PX
MR-J3-22KB-PX
MR-J3-11KB4-PX
MR-J3-15KB4-PX
MR-J3-22KB4-PX
When using cooling fans, install them using the mounting holes provided in the bottom of the
regenerative option. In this case, set "
2 cooling fans
(92 92, minimum air flow: 1.0m
Do not remove
Regenerative option
the short bar.
P
C
G3
(Note)
G4
Regenerative option
Resistance [ ]
model
MR-RB5E
MR-RB9P
MR-RB9F
MR-RB6B-4
MR-RB60-4
MR-RB6K-4
Bottom
TE1
)
3
Mounting screw
4-M3
Regenerative power [W]
Without
cooling fans
6
500
4.5
850
3
850
20
500
12.5
850
10
850
FA" in parameter No. PA02.
Top
MR-RB5E 9P 9F 6B-4 60-4 6K-4
TE
G4 G3 C
11 - 29
With
cooling fans
800
1300
1300
800
1300
1300
P