Mitsubishi Electric Melservo-J3 Series MR-J3-B Instruction Manual page 322

Melservo j3 series general-purpose ac servo sscnet compatible
Hide thumbs Also See for Melservo-J3 Series MR-J3-B:
Table of Contents

Advertisement

13. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
(1) Enabling control function of magnetic contactor (parameter No.PA02
Connecting the magnetic contactor control connector (CNP1) to the operating coil of the magnetic contactor
enables to control the magnetic contactor.
Power supply
Control circuit
power supply
(Note)
Note. Stepdown transformer is required when coil voltage of the magnetic contactor is 200V class, and the converter unit and the drive
unit are 400V class.
When the converter unit receives a start command from the drive unit while the magnetic contactor control
connector (CNP1) is connected to the magnetic contactor (refer to section 13.3.2 (1)), CNP1-2 and L
conduct in the converter unit. Then the control circuit power is supplied to turn ON the magnetic contactor
and the main circuit power is supplied to the converter unit.
Either when an alarm occurs on the converter unit or the drive unit while the control function of the magnetic
contactor is enabled, or when the forced stop (EM1) of the converter unit or the drive unit is turned OFF, the
switch between CNP1-2 and L
automatically shut off.
To automatically shut off the main circuit power supply by alarm, enable the control function of the magnetic
contactor.
(2) Disabling control function of magnetic contactor (parameter No.PA02
When not connecting the magnetic contactor control connector (CNP1) to the operating coil of the magnetic
contactor, configure the circuit to shut off the main circuit power supply when detecting an alarm since the
main circuit power supply is not automatically shut off even when an alarm occurs on the converter unit or
the drive unit.
NFB
MC
MC1
MC2
Motor
Drive
thermal relay
unit
RA1
RA2
RA3
RA4
Controller
Converter
forced stop
unit
in the converter unit is disconnected and the main circuit power supply is
21
13 - 25
1 (initial value))
Converter unit
L
1
L
2
L
3
L
11
L
21
CNP1
1
2
Operation
Forced stop
-ready
EM1
OFF/ON
0)
MC
SK
21